PNUEMATICS & A/C System Flashcards

1
Q

How is BLEED AIR normally supplied to the CENTER Duct?

A

From the Crossover manifold which is supplied from either engine or the APU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which Systems use BLEED AIR from the CENTER Duct?

A
  1. ADP (Air Driven Pump) for C HYD Sys
  2. AFT & BULK Cargo Compartment heat
  3. C HYD Sys Resv
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

If the OVHT warning light illuminated simultaneously with the ENG BLEED OFF light, what has happened?

A

A Bleed Air malfunction has occurred (excessive bleed air temp) and the ENG BLEED VALVE has closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How are the BLEED VALVES actuated?

A

Electro-pneumatic- Electronically charged, pneumatically operated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

There are LOOPS outside of each duct, if hot air is sensed, what light will illuminate?

A

DUCT LEAK

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

If you see the OVRHT light, what will the aircraft attempt to do?

A

Close the ENG BLEED VALVE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

On the Cabin Rate knob, there is a tick mark. What does this mean?

A

Cabin rate between 300-500 FPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which temperature zone controls the output of the air conditioning PACs during automatic temperature control?

A

The compartment demanding the coolest temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the purpose of the TRIM AIR SYSTEM?

A

Adds warm air to control individual zone

temperature as required by the Zone

Temperature Controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly