px practice test | review questions Flashcards

1
Q

under what circumstance is the occupant load of a building allowed to increase?

A

the occupant load is allowed to increase if all other code requirements are met AND the occupant load does not exceed one occupant per 7 sf

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

what is included in rentable area?

A

everything the tenant will pay rent on

this includes all interior floor area

this excludes all vertical penetrations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

what is the calculation for rentable area?

A

rentable area = usable area x load factor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

what is the most effective method of evaluating a client’s corporate culture?

A

conducting interviews

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

who establishes the construction allowance during a tenant lease agreement?

A

the building owner

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

a 1-hour rated wall needs a door with what time rating?

A

20-minute door

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

if the glass entrance doors to a suite need to be replaced, what type of door will go in its place?

(the partition is 1-hour rated)

A

the door will have to be replaced with either a 20-minute solid door with glass that is also 20-minute rated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

what is the difference between the slope of a walking surface and a ramp?

A

the slope of a walking surface cannot exceed 1:20

once that slope is exceeded the surface is classified as a ramp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

which of the following light fixtures takes the longest to warm up?

  • halogen
  • hid
  • fluorescent
  • incandescent
A

hid (high-intensity discharge)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

which of the following elements of a stair must be designed to specific accessibility requirements?

  • riser height + handrail
  • tread depth + riser height
  • nosing + handrail
  • riser height, tread depth, handrail
A

nosing + handrail

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

what is the maximum height of a commercial, accessible stair riser?

A

7”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

what type of slab cannot be penetrated for a stair opening?

A

post-tensioned slabs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

why can a post-tensioned slab not be penetrated?

A

a stair opening would typically require cutting an area larger than the spacing of the post-tensioned cables

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

what cost typically accounts for the largest percentage of overhead?

  • capital expenses
  • indirect labor costs
  • profit
  • salary rates
A

indirect labor costs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

if a client’s program requirements change, who is responsible for the additional services?

A

the designer is responsible for the implementation of the changes, but the client is responsible for the payment of the add services

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

which of the following would not be a ration used to measure the status of a business’s financial health?

  • net profit before taxes
  • revenue per technical staff
  • overhead rate
  • chargeable ratio
A

chargeable ratio

17
Q

what type of business structure allows for the most control by its founders?

A

a partnership

18
Q

if a designer believes that the payment requested by the contractor does not add up with the amount / quality of work completed, what is the best course of action?

A

the designer should only certify the amount that they believe represents the work completed

19
Q

what is a scoping provision?

A

scoping provisions are requirements that dictate how many accessible elements must be proivided

20
Q

based on ibc, in an office setting, how many watts per square foot are allowed to light the building?

21
Q

depending on the occupancy, how is a type v building limited?

A

by a few thousand square feet in area and 1-2 stories in height

22
Q

openings with more than 24” in depth at doors shall provide a clear opening of __________ minimum?

23
Q

what is the test method for flammability of wall + ceiling assemblies?

24
Q

glazing in fire-rated partitions / sidelites may not exceed how many square inches?

25
which occupancy group is the most restrictive and why?
a - assembly these groups are the most restrictive because the deal with the largest groups of people
26
the bottom of a pendant light is required to be how many inches above the finished floor?
94"
27
what is the clearance needed between the cooking surface and the bottom of the wall cabinet?
30"
28
a compact filing system is an example of what type of load?
live load
29
what examples are included in live loads?
- people - furniture - moving equipment
30
before executing a post-occupancy review, what should the team do prior to collecting data? - create the research hypothesis - validate the research tool - review the business case - define the performance metrics
validate the research tools
31
does the post-contract phase come near the beginning of a project or closer to project closeout?
at the beginning of a project, directly after pre-contract work
32
what is the main purpose of a gantt chair?
to show a simple timeline of individual project tasks
33
under which masterformat section would one find acoustical ceilings?
division 09 - finishes