QUICK REFERENCE CHART Flashcards
Page 86
1–3/4” Handline Tips
50 PSI Nozzle Pressure
What is the GPM for the 3/4” tip
100 GPM
1–3/4” Handline Tips
50 PSI Nozzle Pressure
What is the GPM for the 7/8” tip
150 GPM
1–3/4” Handline Tips
50 PSI Nozzle Pressure
What is the GPM for the 15/16” tip
180 GPM
1–3/4” Handline Tips flow at what PSI?
50 PSI
2–1/2” Handline Tips
50 PSI Nozzle Pressure
What is the GPM for the 1” tip
200 GPM
2–1/2” Handline Tips
50 PSI Nozzle Pressure
What is the GPM for the 1–1/8” tip
250 GPM
2–1/2” Handline Tips
50 PSI Nozzle Pressure
What is the GPM for the 1–1/4” tip
300 GPM
2–1/2” Handline Tips flow at what PSI?
50 PSI
Master Stream and Ladder Pipe
80 PSI Nozzle
What is the GPM for the 1–1/4” tip
400 GPM
Master Stream and Ladder Pipe
80 PSI Nozzle
What is the GPM for the 1–3/8” tip
500 GPM
Master Stream and Ladder Pipe
80 PSI Nozzle
What is the GPM for the 1–1/2” tip
600 GPM
Master Stream and Ladder Pipe
80 PSI Nozzle
What is the GPM for the 1–3/4” tip
800 GPM
Master Stream and Ladder Pipe
80 PSI Nozzle
What is the GPM for the 2” tip
1000 GPM
1–3/4” Handline Nozzle 150’ or 200’ Preconnects
Akron TurboJet 75 PSI
For 95-125-150 GPM, pump at what PSI?
110 PSI
1–3/4” Handline Nozzle 150’ or 200’ Preconnects
Akron TurboJet 75 PSI
For 200 GPM, pump at what PSI?
150 PSI
1–3/4” Handline Nozzle 150’ or 200’ Preconnects
Akron TurboJet 100 PSI
For 95-125-150 GPM, pump at what PSI?
135 PSI
1–3/4” Handline Nozzle 150’ or 200’ Preconnects
Akron TurboJet 100 PSI
For 200 GPM, pump at what PSI?
175 PSI
1–3/4” Handline Nozzle 150’ or 200’ Preconnects
( Akron SaberJet Combination Nozzle )
Pump at ____ PSI to achieve both:*
___ GPM Fog
___ GPM Solid ( 7/8 )
___ GPM Solid ( 15/16 )
125 PSI
135 GPM FOG
150 GPM Solid ( 7/8 )
180 GPM Solid ( 15/16 )
Relay Pumping
___ PSI plus ___ PSI per 100’ of 5” hose adjust as needed to maintain 50 PSI of residual pressure on the engine being supplied. DO NOT EXCEED ___ PSI
50 PSI
10 PSI
200 PSI
Residual Pressure Drops
Less than 10%
3 more lines of equal GPM
Residual Pressure Drops
10%-20%
2 more lines of equal GPM
Residual Pressure Drops
20%-25%
1 more line of equal GPM
Greater than 25%
You may be able to pump smaller lines only
Standpipe: Initial Pressure ____
100 PSI **Be prepared to adjust based on circumstances