A. Odorless when mixed with air
B. An ether like odor when mixed with air
C. Explosive when mixed with air
D. Boils at a higher temp than R-12 at atmospheric pressure
A. Odorless when mixed with air
A. Turn on chilled water pumps and open the bypass to lighter load
B. Install larger fuse to take the initial load, and then turn on the cooling tower fans
C. Turn on chilled water pump, condenser water pumps and cooling tower fans
D. Set the thermostat a few degrees higher
C. Turn on chilled water pump, condenser water pumps and cooling tower fans
1 Accomplish lower temperature
2 Permit the use of inexpensive lubricating oil
3 Avoid the need for very high compression ratios
4 Divide the cooling load between two compressors
Accomplish lower temperature
A. The possibility of lower water out temp
B. There is no dependence on natural wind velocity
C. Use a smaller tower size
D. All of the above
D. All of the above
A. 101.3
B. 101.28
C. 101.26
D. 103.2
A. 101.3
A. Economizer
B. Purge unit
C. Air bleed
D. Pressure relief device
B. Purge unit
A. High side
B. Low side
C. Either side of the system
D. Neither side of the system
B. Low side
A. Gate valve causes less leakage
B. Globe valve causes more leakage
C. All valves are the same
D. Gate valve causes more leakage
D. Gate valve causes more leakage
A. Stuffing box
B. Electro-mechanical seal
C. Mechanical seal
D. All of the above
C. Mechanical seal
A. 450 F
B. 280 F
C. 212 F
D. 800 F
B. 280 F
A. Low cond. Temp low cond. water temp
B. High cond. Temp, high cond. Water temp
C. High cond. Temp low cond. Water temp
D. Low cond. temp, high cond. Water temp
C. High cond. Temp low cond. Water temp
A. Requires a smaller charge
B. Requires a larger charge
C. Requires the use of a TXV for proper feed
D. Water has to be drained daily
D. Water has to be drained daily
Shell and tube condensers have the advantage of:
A. Removing heads for cleaning the water sides of the tubes
B. The refrigerant connections does not have to be disrupted
C. Using acid for clean
D. Both A and B
B. The refrigerant connections does not have to be disrupted
A. Removing heads for cleaning the water sides of the tubes
B. The refrigerant connections does not have to be disrupted
C. Has less chance of developing leaks
D. Both A and B
B. The refrigerant connections does not have to be disrupted
A. 12,000 per hour
B. 360,000 per minute
C. 12,000 per minute
D. 360,000 per hour
D. 360,000 per hour
A. 66
B. 64.4
C. 65
D. 62
B. 64.4
A. Easy fabrication
B. East durability
C. High Thermal conductivity
D. Flexibility
B. East durability
A. Solenoid valve, drier and sight glass
B. Receiver, drier, solenoid valve and sight glass
C. Muffler, drier, sight glass, and solenoid valve
D. Accumulator, muffler, drier, sight glass
A. Solenoid valve, drier and sight glass
A. 565
B. 4227
C. 1808
D. 1205
D. 1205
A. Recycling
B. Recovering
C. Reclaiming
D. Purging
B. Recovering
A. Solenoid valve
B. High pressure cut-out
C. Low pressure cut-out
D. Thermostat
D. Thermostat
A. Flooded evaporator
B. Starved evaporator
C. Excessive superheat
D. Low superheat
C. Excessive superheat
A. Mostly liquid, some vapor
B. Mostly vapor, some liquid
C. Superheated vapor
D. Highly superheated vapor
C. Superheated vapor
A. Centrifugal chilled water pump
B. Reciprocating condenser water pump
C. Reciprocating chilled water pump
D. Centrifugal condenser water pump
A. Centrifugal chilled water pump