Section F Ontario Fire Code – Parts 3 & 5 Flashcards
(32 cards)
F-1. (OFC Div. B. 3.4.2.1 (4)) Propane powered forklift trucks shall be equipped with a portable fire extinguisher having a minimum rating of: a) 3A:10B:C b) 20BC c) 2A:30B:C d) Not required
c) 2A:30B:C
F-2. (OFC Div. B. 3.2.2.5 (1)) How far must stickered lumber piles be stored away from buildings? a) 4.5m b) 15m c) 6m d) 10m
b) 15m
F-3.
(OFC Div. B. 3.5.1.3)
In an automobile wrecking yard, gas tanks on vehicles to be salvaged must be:
a) Removed from the vehicle prior to salvage operations
b) Drained of all liquids prior to salvage operations
c) Capped and or sealed off prior to salvage operations
d) Drained and ventilated prior to salvage operations
d) Drained and ventilated prior to salvage operations
F-4. (OFC Div. B. 3.2.2.27) In a lumber storage yard where fire protection cannot be provided by municipal street hydrants in order to confine and control a fire, the hydrant system shall be extended into the yard so that all parts of the lumber yard can be reached by not using more than: a) 30m of hose b) 90m of hose c) 60m of hose d) 25m of hose
c) 60m of hose
F-5. (OFC Div. B. 3.3.2.2 (1)) In an unsprinklered warehouse used for indoor general storage, the maximum area of individual storage piles shall not exceed: a) 500m2 b) 1000m2 c) 250m2 d) 450m2
a) 500m2
F-7. (OFC Div. B. 3.4.2.2 (1)) Combustible materials shall be stored how far from the charging installation for battery powered fork lift trucks: a) 4.5m b) 1.5m c) 3.0m d) 5.0m
b) 1.5m
F-8. (OFC Div. B, 5.17.2.6 (2)) How often shall welding and cutting equipment be tested for leaks? a) Monthly b) Weekly c) Daily d) At each use
a) Monthly
F-9. (OFC Div. B. 5.6.1.5) Compressed gas cylinders shall be stored in an area where the ambient air temperature does not exceed: a) 37.8°C b) 52°C c) 66°C d) 73°C
b) 52°C
F-10.
(OFC Div. B. 3.5.1.10)
In a salvage yard, the phone number of the Fire Department must be conspicuously posted:
a) In working locations in the open yard
b) In all buildings in the yard
c) In attended locations throughout the open yard
d) In working locations in the open yard and in each building
d) In working locations in the open yard and in each building
F-11.
(OFC Div. B. 5.14.9.5 (2) and 2.4.3.2)
In a room where pin refinishing is being carried out, there must be a no smoking sign posted which conforms to the following:
a) Black lettering 50mm high with a 12.5mm stroke on a yellow background
b) A symbol 150mm x 150mm
c) Both a) & b)
d) a) or b)
d) a) or b)
F-12. (OFC Div. B. 3.4.2.1 (4)) Fuel fired industrial trucks in an outdoor tire storage yard shall be equipped with a listed portable fire extinguisher having a minimum rating of: a) 2A:30B:C b) 5B:C c) 10B:C d) 1A:5B:C
a) 2A:30B:C
F-13. (OFC Div. B, 3.2.3.6 (1)(a)) The clear space between a wood chip pile 16m in height and a wood frame building shall be: a) 16m b) 32m c) 9m d) 18m
b) 32m
F-14. (OFC Div. B, 3.3.1.6) In a warehouse containing tire storage, what clearance must be maintained between piles of tires and supporting columns? a) 600mm b) 914mm c) 457mm d) Half the height of the adjoining pile
a) 600mm
F-15. (OFC Div. B. 3.2.2.7) In a lumber yard, piles of sawdust may be accumulated to a maximum pile height of: a) 3m b) 1.5m c) 914mm d) Not permitted
d) Not permitted
F-16.
(OFC Div. B. 5.12.5.2)
An electric motor for an exhaust fan serving a spray booth shall be placed:
a) In the exhaust duct
b) In the spray booth
c) Outside of the spray booth and exhaust duct
d) In an electrically grounded location
c) Outside of the spray booth and exhaust duct
F-17.
(OFC Div. B. 5.2.1.2)
The storage of ammunition shall be in conformance with:
a) Canadian General Standards Board
b) American National Standards Institute
c) Explosives Act (Canada)
d) Regulations for the Transport of Dangerous Commodities
c) Explosives Act (Canada)
F-18. (OFC Div. B. 5.12.4.4) An access door shall be installed in a spray booth exhaust duct for: a) Inspection purposes b) Maintenance purposes c) Access to exhaust fan d) Cleaning purposes
d) Cleaning purposes
F-19.
(OFC Div. B. 5.6.2.4 (3)(c))
Cylinders containing a flammable compressed gas which is heavier than air must not be stored:
a) In a basement or below grade
b) On the main floor
c) In an unsprinklered building
d) In a fire compartment having less than a 1 hour fire-resistance rating
a) In a basement or below grade
F-20. (OFC Div. B. 3.2.2.6) Lumber stored outdoors in a pile with a height of 3m must be how far from adjacent vegetation? a) 4.5m b) 3m c) 6m d) 15m
a) 4.5m
F-21.
(OFC Div. B, 3.2.1.1 (1))
An outdoor storage pile of tires is 100m2 in area and 2.5m in height. The public water system supplying water to this storage yard must supply how much water?
a) 3780 L/min. for 3 hours
b) 1860 L/min. for 3 hours
c) Enough to fill an on-site reservoir in conformance with NFPA 1231 Appendix B-1984 “Standard on Water Supplies for Suburban and Rural Fire Fighting”
d) No requirement for water supply due to the size of the pile
d) No requirement for water supply due to the size of the pile
F-22.
(OFC Div. B. 5.13.3.4)
A dip tank having a capacity in excess of 550L of a combustible liquid must have:
a) A 200mm diameter overflow pipe leading to a safe location outside the building
b) An overflow pipe sized in accordance with Table (5.13.3.A.) from Division B, Section 5.13 of the Ontario Fire Code
c) A trapped, 200mm diameter overflow pipe leading to a safe location outside the building
d) A trapped overflow pipe sized in accordance with a Table (5.13.3.A.) from Division B, Section 5.13 of the Ontario Fire Code
b) An overflow pipe sized in accordance with Table (5.13.3.A.) from Division B, Section 5.13 of the Ontario Fire Code
F-23. (OFC Div. B. 5.4.3.4 (1)) A vault containing 3250 kg of cellulose nitrate plastics must be separated from the remainder of the building by a fire separation having a fire resistance rating of: a) 1 hour b) 1.5 hours c) 2 hours d) 3 hours
b) 1.5 hours
F-24. (OFC Div. B. 5.12.10.11) The surface temperature of an electrostatic fluidized bed coating area shall not exceed: a) 37.8°C b) 66.0°C c) 10.0°C d) 50.0°C
b) 66.0°C
F-25. (OFC Div. B. 3.3.4.6 (1)) The clearance between sprinkler head deflectors and the tops of baled storage piles of combustible fibres shall not be less than: a) 457mm b) 300mm c) 914mm d) 650mm
a) 457mm