Setpoints Flashcards

(26 cards)

1
Q

What is the NCP trip setpoint for high stator temperature?

A

311 degrees F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the NCP trip setpoint for pump bearing temp?

A

225 degrees F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the NCP trip setpoint for #1 Seal outlet temperature?

A

235 degrees F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the NCP trip setpoint for motor bearing temperature?

A

195 degrees F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the NCP trip setpoint for pump shaft vibration?

A

greater than 20 Mils

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the NCP trip setpoint for motor frame vibration?

A

greater than 5 mils

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the NCP trip setpoint for #1 seal deltaP?

A

less than 200 psid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the setpoints for the S/G safeties?

A

1175, 1190, 1205, 1220, 1230 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When does a PZR safety valve open? What the Bases for Safeties?

A

2485 psig
-NC integrity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the rods speed for SD bank rods?

A

64 steps/minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the rods speed for control banks rods?

A

48 steps/minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the rods speed when rods are in Manual?

A

48 steps/minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How much seal flow goes to the #1 seal and where does it leak off to?

A

3 gpm
seal leak off goes to the VCT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How much seal flow goes to the #2 seal and where does it leak off to?

A

3 gph
seal leak off goes to the NCP standpipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How much seal flow goes to the #3 seal and where does it leak off to?

A

100 cc/hour
seal leaks off goes to the NCDT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the setpoint for C-16?

A

2/4 Tave less than or equal to 553 degrees F
Tave less than 20 degrees below Tref

17
Q

What is the setpoint for C-7A and where does it go?

A

-10% step change or -5%/min rate change on 2/3 Turbine Impulse Pressure channels
-Goes to the arming solenoid for the condenser dumps

18
Q

What is the setpoint for C-7B and where does it go?

A

-30% step change or -15%/min rate change on 2/3 Turbine Impulse Pressure channels
-Goes to the arming solenoid for the atmospheric dumps.

19
Q

What is the heat up/cooldown rates for the NC system per Tech Spec 3.4.3 (RCS P/T limits)?

A

Heat up is 60 degrees per hour/cooldown is 100 degrees per hour

20
Q

What is the heat up/cooldown rates for the Pressurizer per SLC 16.5-4 Pressurizer?

A

Heat up is 100 degrees per hour/Cooldown is 200 degrees per hour

21
Q

What is the highest subcooling that ICCM can read?

A

200 degrees F

22
Q

What is the lowest subcooling that ICCM can read?

A

-35 degrees F

23
Q

At what pressure does the S/G PORVs open?

24
Q

At what pressure does the S/G PORVs close?

25
What is the SSE (Safe Shutdown Earthquake) limits?
SSE for Catawba is .15g horizontal or .10g vertical
26
What is the OBE (Operational Basis Earthquake) limits?
OBE for Catawba is .08g horizontal or .053g vertical