The fire department pumper is the core unit of the fire service and is sometimes expected to fill several roles such as:
Rescue, hazardous materials or medical responses
Fire apparatus are classified according to:
Their primary function for which they are designed
Fire apparatus are classified according to:
The primary function for which they are designed
The fire department pumper is the core unit of the fire service and is sometimes expected to fill several roles such as
Rescue, hazmat, or medical response
The main purpose of a fire dept. pumper is to
Provide adequate water pressure for effective fire streams.
Nfpa 1901 specifies a minimum pump capacity of… And water tank capacity of…
Pump 750 with each increase in increments of 250
Tank 300
In addition to a fire pump the apparatus must be equipped with:
Intake and discharge pump connections, pump controls and gauges, as well as a variety of hose sizes and types. The hoses include intake, supply, and attack hose.
Equipment commonly found on pumpers:
Ground ladders Scba Forcible entry tools Salvage tools and equipment Portable water tank Emergency medical equipment
The foam proportioning systems commonly found on municipal fire pumpers are:
Scaled down versions of those used for industrial fire pumpers. Foam tanks usually range from 20-100 gallons.
The articulating or telescoping devices most commonly combined with pumpers generally range in height from:
50-75 feet
Mini pumper and midi pumper define pumping apparatus:
Smaller than a full size pumper
Apparatus typing:
Categorizing pumping apparatus and mobile water supply apparatus based on capability.
Mobile water supply apparatus, as stated in nfpa 1901 are equipped with a tank capacity of at least:
1000 gallons
Mobile water supply apparatus (tenders and tankers) are used:
To transport water to areas where a water system is nonexistent or inadequate.
Mobile water supply apparatus h ave 2 basic functions on the fireground:
- The water tender may be used in a mobile shuttle operation
- The apparatus may also be used as a stationary reservoir or nurse tender.
Combating wildland fires requires an apparatus design that is:
Lightweight, highly maneuverable, and all-terrain.
A pump and roll system uses a seperate:
Motor or a power take off (pto) to power the fire pump.
Arff apparatus are used to provide:
Immediate suppression of flammable liquid fires and suppression of vapors from fuel spills.
Nfpa 414 standard for arff vehicles classifies apparatus by:
The type of suppression agents carried, agent capacity, or numbers of drive wheels.
Pg 20
Local jurisdictions devide arff apparatus into 3 general categories:
Major fire fighting vehicles
Rapid intervention vehicles
Combined agent vehicles
Pg 20
Jurisdictions may use fireboats to protect hazards:
On and adjacent to waterways.
Pg 21
Functions of modern fireboats include:
Ice and water rescue,
Emergency medical services
Fire fighting
And relay pumping to land based apparatus.
Pg 21
Some fireboats have capacities as high as ……. Gpm. Individual mater streams devices on vessels may discharge large volumes of water sometimes in excess of…..
50,000 gpm capacity
10,000 gpm discharges
Pg 21
Arial apparatus equipped with a fire pump should always be positioned with consideration:
Of the reach of the aerial device.
Pg 21