Elec Flashcards

(22 cards)

1
Q

What is the minimum battery voltage?

A

25.6V

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What should be done if battery voltage is 25.5V or below on preflight?

A

Charge batteries using external power by setting BAT pushbuttons to AUTO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How long should the batteries be charged before rechecking voltage?

A

20 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How do you conduct the battery check?

A

Select ELEC ECAM page, turn BAT 1 and 2 OFF then ON, check charging current <60 amps and decreasing within 10 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

If the battery check fails, what should you do?

A

Wait for charging to complete and repeat the test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Describe the electrical power system.

A

3-phase 115/200V AC 400Hz system + 28V DC; generators create AC, some converted to DC; all generators can power the full network

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If all AC power is lost, what happens?

A

Battery DC is converted to AC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What GEN pushbutton indication is expected before engine start?

A

FAULT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is an IDG?

A

Integrated Drive Generator — converts variable engine RPM to constant output frequency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How is an IDG disconnected?

A

Lift red guard, push IDG pb (not longer than 3 sec) — only after confirming with other pilot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Can a flight crew reconnect an IDG?

A

No — maintenance only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Describe the BUS TIE in AUTO.

A

Connects AC BUS 1 and 2 if needed; enables APU GEN or EXT PWR to power the system; prevents simultaneous sources

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

If GEN 1 fails, how is AC BUS 1 powered?

A

Through BUS TIE using GEN 2 (or APU GEN)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How is the AC ESS BUS normally powered?

A

From AC BUS 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If AC BUS 1 fails, how is AC ESS BUS powered?

A

Automatically from AC BUS 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What indicates that AC ESS is being powered by AC BUS 2?

A

AC ESS FEED ALTN light (only when manually selected)

17
Q

What does a GALLEY fault light indicate?

A

At least one generator is above 100% load

18
Q

What does the GALLEY pushbutton do in AUTO?

A

Sheds main galley power if only 1 GEN is online

19
Q

How is the BATTERY BUS normally powered?

A

Through DC BUS 1 via the DC tie contactor

20
Q

What buses are powered by the EMER GEN?

A

AC ESS, AC ESS SHED, DC ESS via ESS TR, DC ESS SHED

21
Q

What does a BAT FAULT light indicate?

A

Battery charging current is out of limits; BAT contactor opens

22
Q

When are the batteries connected to the BATTERY BUS?

A

APU start, battery charging, or if both AC BUS 1 & 2 are lost and airspeed <100 knots