Oxygen Flashcards
(10 cards)
What happens when a pilot pushes the CREW SUPPLY pushbutton?
Valve opens to supply low pressure oxygen to the masks
How does the passenger fixed oxygen system work and how long does it last?
Chemical oxygen generators last for approximately 15 minutes
What does the illumination of the SYS ON light mean? Does this mean that all the masks have deployed?
The signal has been sent to release the oxygen mask doors, but some masks may have to be deployed manually
What causes automatic deployment of the masks?
Cabin altitude reaching approximately 14,000 ft
How is the crew oxygen mask microphone deactivated when the mask is stowed?
The RESET control slide will accomplish this – it does not happen automatically
What indication would a pilot have of a crew oxygen cylinder thermal discharge?
The green disk on the lower left side of the forward fuselage would be missing
Could the passenger fixed oxygen mask provide oxygen for anything other than depressurization?
No, unless there is a written FCOM or QRH procedure for its use
On the ground, if there is an amber half frame around the CKPT OXY PSI box, where would you look to see if you have enough oxygen for the flight?
FCOM – Limitations – Oxygen
How can a flight crew determine the flight crew oxygen pressure required for the flight?
FCOM – Limitations – Oxygen – Minimum Flight Crew Oxygen Pressure
What do the minimum oxygen bottle pressure quantities guarantee?
Preflight checks; oxygen use by one pilot in the cockpit; system leakage; 15 mins emergency descent + 105 mins at FL100 for 2 pilots; 15 mins 100% oxygen at 8,000 ft for all