For any situation, the proper distance between the objective and the aerial apparatus affords the maximum _________, the best ______, and adequate ________.
stability; climbing angle; extension
pg 564
If the fire building is up to and including four stories and/or no greater than 60ft, engine companies should park on the ______ to the building, and aerial apparatus should park on the _________ of the engine.
side of the street closest; outside
pg 567
If the building is five stories or more (more than 60ft), the engine takes the ________ position and the aerials park _______ to the building.
outside; next
pg 567
__________ is the footprint of the building or structure that can be covered/reached with the tip of the aerial ladder or elevating platform.
Scrub area
pg 567
One visual indicator of a compressed asphalt surface due to extreme heat is when the asphalt “_________”, creating a shining, glass-like surface.
bleeds
pg 568
Depending on the operational capabilities of the apparatus and the severity of the grade, apparatus with two rear stabilizers may need to face
uphill
pg 570
___ft between the device and overhead electric lines of less than 350 kilovolts.
20
pg 571
For high-tension lines over 350 kilovolts, OSHA requires _____ of clearance.
50ft
pg 571
__________ is a result of the length of the apparatus behind the rear axles that swings to the outside of a turn, creating a potential contact area.
Tail swing
pg 572
Stability of aerial apparatus can improve by operating the aerial device in line with the ________ axis.
longitudinal
pg 573
Any angle _________ to the apparatus offers the least stable position.
perpindicular
pg 573
_________ acts as the usable part of an aerial device that extends from the apparatus.
Aerial reach
pg 574
The rotation interlock will stop rotation to the short-jacked side a ____ degrees, unless the truck has envelope controls that allow for operation over the short-jacked stabilizers in proportion to deployment.
5
pg 575
_______ refers to positioning the apparatus in a location that maximizes efficiency for the fireground operation.
Spotting
pg 577
When approaching from the _______ side, the apparatus should park past the building, and operate the aerial device from the rear of the truck.
uphill
pg 577
When approaching from the ________ side, stop the apparatus short of the building. Operate the aerial over the cab.
downhill
pg 577
The collapse zone is ___ times the building’s height.
1.5
pg 580
Even after receiving halt confirmation, keep the aerial device at least ___ft above the level of the rails as an added protection.
25
pg 582
Allow the standard ___ safety distance from the lines if electric lines are present.
10ft
pg 583
If the tip of the device is to be placed in an aircraft doorway, the apparatus should be positioned as if to access
the window of a building
pg 585
If the objective is to provide access over a wing or remove victims from a wing, the positioning principles resemble those for providing access to the
roof
pg 585
Avoid spotting the apparatus in a position that hinders the deployment of the aircraft
emergency slides
pg 586
When operating at storage tank fires, the D/O should always position the apparatus ________ the dike’s walls, unless the roadway lies on top of the dike.
outside
pg 586