CH3 Flashcards

(25 cards)

1
Q

When positioning for exposure protection, consider the apparatus as a

A

potential exposure
pg 125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

If handlines or portable master streams are to be used, the pumper must be positioned in

A

Close proximity to the structure or incident to allow an effective water supply.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Structures built with lightweight materials and buildings with faux facades, parapets, or cantilevers can also suffer

A

Rapid collapse
pg 126

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Structures that are ___, ____, or _____ may pose a higher risk even before a fire or other catastrophe.

A

Old, poorly maintained, or under construction
pg 127

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Depending on the incident, apparatus equipment, and personnel operating within ____ of the base of a high-rise fire may need to be protected from falling glass and debris.

A

200ft
pg 128

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

If a structure is fewer than 5 floors tall, the attack pumper is positioned on the

A

side of the street closest to the structure and aerial apparatus are placed outboard of the pumper.
pg 128

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When the fire structure is 5 floors or more, the attack pumper takes the outside position to allow the aerial apparatus

A

Maximum reach
pg 128

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

To effectively supply an FDC, the D/O should position the pumper as close as possible to the water

A

Source
pg 129

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Drafting operations are required when a pumper must be supplied from a static water supply source such as a

A

Dry hydrant, cistern, storage tanks, lake, or stream
pg 131

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Preference should be given to drafting locations accessible from a

A

hard surface that require a minimum length of hard intake hose or lift.
pg 131

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

____ consist of an intake hose connection on the shore and a length of pipe extended into the water with a strainer on the end.

A

A dry hydrant
pg 132

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

One hydrant that has sufficient capacity to maintain the minimum residual pressure for the total fire flow is used to supply two pumpers.

A

Dual pumping
pg 134

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

____ pumping operations are a form of relay pumping with the pumpers positioned close together in the supply hose layout.

A

Tandem
pg 134

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Tandem pumping may be needed when pressures higher than a single engine is capable of supplying are required, and also when it is necessary to supply a

A

high-rise or standpipe system
pg 134

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

In ____ pumping operations, apparatus may be positioned up to 300ft apart.

A

Tandem
pg 134

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If the first-arriving unit has no immediate orders for later-arriving apparatus, the officer may call for _____ staging to be implemented while the incident is investigated.

A

Level I
pg 135

17
Q

In Level II staging, one or more apparatus staging areas may be designated by the

A

Operations Section Chief, from which the IC can draw additional resources.
pg 135

18
Q

_____ may be expanded or contracted with the changing dynamics of the incident.

A

Control zones
pg 136

19
Q

Also called the restricted zone, exclusion zone, or red zone.

A

Hot zone
pg 136

20
Q

The ____ zone, also called the limited access zone or yellow zone.

A

Warm zone
pg 136

21
Q

____ is used to provide support for operations in the hot zone and to decontaminate personnel and equipment exiting the hot zone.

A

Warm zone
pg 136

22
Q

Also called the support zone or green zone.

A

Cold zone
pg 136

23
Q

Apparatus and personnel should be ___ of the main body of the fire as wildland fires move ____ faster than on flat terrain or downhill.

A

downhill; uphill
pg 139

24
Q

Responders must consider all railroad tracks to be

A

“Live” (active)
pg 142

25
Apparatus should maintain a clear zone of at least ____ from railroad tracks to prevent contact with objects on the railroad cars.
25ft pg 142