Chapter 23: Facility design, layout, and organization Flashcards

1
Q

first step to building a new facility

A

assemble a committee of professionals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

the committee should include the following (5)

A
contractor
architect
designer
lawyers
people involved in running the facility
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

4 phases of building a new facility

A

predesign
design
construction
preoperation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

first step in building a new facility and should consist of a needs analysis, feasibility study and master plan

A

predesign phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

at the end of the predesign phase this individual should be hired

A

architect

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

step in which designers and experts collaborate and determine the needs of the athletic program

A

needs analysis

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

second part of the predesign phase

A

feasibility study

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

should analyze strengths, weaknesses, opportunites, and threats

A

feasibility study

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

the goal of this is to ensure that the financial investment will yield a viable and sustainable return

A

feasibility study

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

the general plan for all phases of the new facility

A

master plan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

this is part of the master plan and sets long and short term goals, as well as staff development and hiring

A

operational plan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

second phase in the process of building a new facility

A

design phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

this is one of the more important aspects of designing the facility

A

traffic flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

the blueprint is created during this phase

A

design phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

longest phase of the entire process

A

construction phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

final steps before the facility can open

A

preoperation phase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

this phase includes finishing the interior décor and hiring a qualified staff

A

preoperation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

various job duties, cleaning, clerical, and administrative are assigned

A

preoperation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

recommended minimum amount of space per athlete is this much per participant

A

100 sqft or 9.3sqm

20
Q

the load bearing capacity of the building should be atleast this

A

100 lbs/sqft

21
Q

where should the supervision location be

A

central location with a clear line of sight and mirrors, may be elevated

22
Q

recommended ceiling height

23
Q

temperature range for a facility

A

68-78* with 72-78* being ideal

24
Q

humidity should not exceed this %

25
air should be exchanged this often via HVAC, fresh air exchange system and fans
8-12 x/hour
26
how many fans per 1200 sqft
2-4
27
max speaker volume
90 decibels
28
ideal speaker location
elevated an in the corners of the rooms
29
Mirror placement
6 inches from any equipment and at least 20 inches from the floor
30
how many phones are needed
at least 1 that is accessible to a person in a wheelchair
31
minimum space between the ends of two barbells/barbell and dumbbells
36 inches
32
distance between lifting equipment and weight trees
36 inches
33
Racks should be placed here, unless this situation exists
against a wall, unless two racks are back to back
34
space between racks and other equipment
36 inches
35
width of walkways
36 inches
36
these are the top priorites when one is deciding on placemtn of equipment in a facitiity
safety and function
37
stretching and warmup space per athlete
49 sqft
38
distance between circuit training machines
24-36(ideal) inches
39
extra space for safety around equipment is called
a safety cushion
40
any designated walkways in the circuit training area should be this wide
4-7ft
41
this freeweight equipment similar to a dumbbell generally is used for dynamic movements and therefore requires more space
kettlebells
42
racks and platfroms in the weightlifting area should be this far apart
3-4 ft
43
space for bikes
24sqft
44
space for stair steppers
24sqft
45
space for skiers
6sqft
46
space for rowers
40sqft
47
space for treadmills
45 sqft