Driver Engineer Guidebook Flashcards

1
Q

There are three factors that affect friction loss. They are:

A
  • The diameter of the hose
  • The volume of water flowing expressed in gpm
  • The length of the hose lay
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

_______ is the pressure at a specific pump discharge.

A

Discharge pressure (DP)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The use of a single hose line, typically 2 1/2”, 4-inch, or 5-inch, to supply two smaller attack lines is referred to as a ______ evolution.

A

wyed line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Connect the appropriate adapter ( ____” FEC or _____” NST)

A

4” FEC or 4 1/2” NST

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Remove the steamer cap of the hydrant, open hydrant until a clear, solid stream is produced; flow for ___ - ___ seconds and then close the hydrant.

A

5 - 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When spotting apparatus with hydrant on the driver’s side you will need _____ feet.

A

15

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When spotting apparatus with hydrant on the officer’s side you will need ____ feet.

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

In sprinkler and standpipe fire protection systems, the vertical pipes that carry water to the upper floors are called _____ and are usually _____ inches or more in diameter.

A

risers , 4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Friction loss should be accounted for if the pipe diameter is less than ____ inches.

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The most common pumping situations for multi-story buildings for this department are:

A
  • Through lines laid up stairs taking into consideration exiting and movement of suppresion forces.
  • Through a line or lines suspended on the outside of a building
  • To a sprinkler system
  • To a standpipe/sprinkler system
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

T or F: It should be noted that elevation means above or below a given point.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

As it relates to hydraulic calculations, the _______ refers to the midline of the pump.

A

elevation point

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

There should never be less than _____ 2 1/2 inch lines supplying a sprinkler system FDC.

A

two

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Suspended Line Ops: The line should be secured at the ____ floor, the ____ floor and every ____ floor between the top and bottom.

A

first, fire, third

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Suspended Line Ops: There should never be more than ___ floors between secured points.

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The pump operator should maintain ____ psi to the sprinkler system FDC.

A

150

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If the fire continues to progress, pertaining to a sprinkler system FDC, increase the DP to _____ psi maximum, by _____ psi increments.

A

200 , 25

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

______ systems are the main source of water supply for fighting fires in high-rise or large buildings.

A

Standpipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Class I :

A

2 1/2 inch oulets for fire department use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Class II :

A

1 1/2 inch hose outlets for occupant use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Class III :

A

Combination standpipe, incorporates both Class I and Class II into a single system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

In most cases, buildings that are _____ stories, or ____ feet and above, have standpipe systems.

A

five, fifty

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Buildings of less than ____ stories may have dry systems, if they have any at all.

A

five

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

All new buildings that are ___ stories or more in height, except for open air parking structures that are a minimum of 20 feet from other structures, shall be fire sprinkler protected.

A

three

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Manual standpipes are usually found in buildings less than ___ feet in height.
50
25
Standpipe systems in taller buildings are automatic ______ systems, which means they have a constant water supply.
wet standpipe
26
The vertical pipe that carries water to the upper floors is called a ____ and is from ___ to ___ inches in diameter and no allowance for FL is necessary.
riser, 4 to 6
27
Remember, it is mandatory that a minimum of ____ 2 1/2 inch lines are used to supply standpipe or sprinkler systems.
two
28
Maximum discharge pressure for 2 1/2 inch hose is _____ psi whereas maximum discharge pressure for LDH is ____ psi.
350 , 185
29
The friction loss of the standpipe system itself; generally accepted to be ____ psi.
25
30
_____ apparatus should be given priority for positioning at building fires.
Aerial
31
Consider spotting the apparatus on the corner of the building allowing access to ____ sides.
two
32
Aerial Rescue: Remove victims in the following priority:
1. Most severely threatened by current conditions. 2. Largest number of groups of people. 3. Remainder of people in the fire area. 4. People in exposed areas.
33
Aerial Operations: If possible, spot the truck ___ feet from the building.
30
34
The best spot, for advancing the pre-connected hand-lines is _______.
in line with the avenue of entry.
35
Aerial Ladder Order of Movement/Operation:
1. Elevate 2. Rotate 3. Extend 4. Lower
36
Relay pumping is used to overcome FL in supply hose and is based on three factors:
- The diameter of the hose - The amount of water required - The distance from the water source to the attack pumper.
37
The maximum speed for laying supply line is ____ MPH.
15
38
Maximum PSI for 4" LDH is _____ psi.
185
39
Remember that the FL in the 4" supply line is 20 psi/100' @ ______ gpm.
1000
40
While operating apparatus equipped with a pressure governor, the attack pumper should be set to the ______ mode, while all others in the relay should be set to _____ mode.
PRESSURE , RPM
41
Attack pumpers, PDP is determined by ______.
fire attack
42
Most frequently, drafting operations are done only for the _______.
Underwriter's Service Test
43
A drafting operation is best done by a crew of _____ or more.
four
44
If the priming device does not discharge water within _____ seconds (1500 GPM pump), perform trouble shooting procedures.
45
45
70 percent of its rated capacity at ____ ft. of lift and 60 percent at ____ ft.
15 , 20
46
For testing purposes, no more than ____ ft. of lift through _____ ft. of hose.
10 , 20
47
For best results, allow ____ feet of water on all sides of the strainer.
2
48
Pressure governor should be kept in the _____ mode until a successful draft is obtained.
RPM
49
For drafting operation, increase throttle between ____ and _____ rpm.
1000 , 1200
50
Prime should be obtained between ____ to ____ seconds.
10 to 15
51
Drafting Operations: Before opening any discharges, increase throttle and maintain ____ to _____ psi on master discharge gauge.
50 to 100
52
A high reading on the vacuum side of the compound gauge with no water entering the pump within the proper time indicates that the suction lift is too ____ or the strainer is obstructed.
high
53
AFFF is used at ___% or ____% to extinguish hydrocarbon fires, and ___% for polar-solvent (water-miscible) fires and oxygenated fuel blends.
1 , 3 , 3
54
``` Application Rates for AFFF: Class A - Wetting ______% Hydrocarbons ______% Ethanol ______% Super Suppression _____% ```
1/2% 1% 3% 6%
55
The trailer (Foam 2) carries two _____ gallon totes of concentrate.
275
56
IN-LINE Eductor : cam lock fitting
cam lock fitting
57
Place foam eductor no more than ____ feet form the nozzle.
200
58
IN-LINE EDUCTOR: Slowly increase pump discharge pressure to ____ psi.
200
59
Using clean water, flush all hoses, educators, and equipment used for product application for a MINIMUM OF ______ MINUTES.
2
60
Prior to flushing for foam clean-up, ensure that the eductor hose is _______ from the cam fitting on pump panel to avoid over pressurizing foam equipment.
disconnected
61
The Elkhart Built-In, By-Pass Eductor System, Model 240-125P is found on _____, ______, & ______ and is rated for _____ gpm flow.
FDP001, FDP005-007, & FDA050 125
62
Elkhart System: Slowly increase pump discharge pressure to ____ psi.
200
63
For Shut-Down Procedures for foam ops be sure to open the _____ and 1 3/4 inch handline and flow water of a minimum of 2 minutes.
Foam System Drain
64
Elkhart Eductors: These eductors are designed to achieve rated flow with an inlet pressure of _____ psi.
200
65
The Foam Pro 2000 system is found on _____ & _____ (these pumpers now use external in-line foam eductors).
FDP 008 & FDP009
66
T or F : It is not necessary to pump at 200 psi for The Foam Pro 2000.
True
67
T or F : Unlike the apparatus equipped with the Elkhart Built-In, By-Pass Eductor system, more than one discharge can be used for operation with The Foam Proportional 2000.
True
68
Spot the foam trailer less than ____ feet away from the driver's side pump panel.
20
69
A ____ is the preferred water supply for foam operations.
hydrant
70
Remove two seals from the bottom of _____ of the 275 gallon foam totes.
ONE
71
Note: No foam will be supplied until the ____ pin is pulled and the _____ ball valve is rotated.
orange , red
72
T or F: The smaller, open end, of the T-fitting is to be used for supplying a Foam Eductor.
True
73
FoaMidget : Connect the _____ colored hose to a | 2 1/2" discharge.
maroon
74
FoaMidget Ops : T or F : DO NOT open the Tank Fill valve.
True
75
Open the 2 1/2" discharge to supply the FoaMidget with _____ psi (maroon line).
150
76
The FoaMidget is a _______ powered device that supplies foam concentrate to the 2 1/2" axillary intake of the pumping apparatus.
venturi
77
The FoaMidget WILL NOT WORK unless ____ psi is maintained.
5
78
Test the brakes by making a sudden stop: the distance traveled my be as little as ____ feet.
ten
79
Any air leak causing the warning buzzer or light to signal low air pressure on a vehicle that has been driven within the last ____ hours, must be reported to the fire department shop.
24
80
The fluid levels should be checked while the engine is ____.
cold
81
A pressure gauge must be used weekly ( _____ for front line apparatus, ______ for reserve apparatus.
Mondays , Sundays
82
T or F : All air pressure testing must be done on a cold tire.
True
83
The voltmeter should show ____ to _____ volts when the charging system is operating normally.
13 to 14.5
84
The fuel should be maintained at not less than ____ of a tank.
3/4
85
UREA : System should be maintained at no less than ____ a tank.
half
86
Urea tanks have a _____ gallon capacity.
5
87
Drive belts must be checked for tightness: about ____ inch of play is correct.
1/2
88
Gauges : Air ____ psi
90-120
89
Gauges : Oil ____ psi at idle / _____ psi maximum.
10-20 , 45-75
90
Gauges : Voltage _____ volts.
13-14.5
91
Gauges : Amps ______ amps.
50-160
92
Gauges : Engine Temp ______ diesel / ______ gasoline.
180-210 / 190-220
93
Gauges : Transmission Temp _______
180-210
94
T or F : All fluids added to the unit must be recorded, except water used to refill the booster tank.
True
95
Research has shown that an antilock brake system can decrease the chance of a vehicle accident by _____%
18
96
T or F : A skidding wheel has less traction than a non-skidding wheel.
True
97
There are four main components to an ABS system:
- Pump - Valves - Controller - Speed sensors
98
The ABS System : In position one, the valve is _____.
open
99
The ABS System : In position two, the valve ____ the line.
blocks
100
T or F: The ABS System: In position three, the valve releases some of the pressure from the brake.
True
101
The ______ watches the speed sensors and controls the valves.
controller
102
Some ABS systems can cycle up to _____ times per second.
15
103
The Jake Brake uses ______ to slow the vehicle.
engine compression
104
If engine does not start within ___ seconds after depressing the START button, release the START button and allow the starter motor to cool for a minimum of ____ seconds before attempting to start the engine again.
15 , 60
105
Shut Down Procedures: Idle engine for ____ to ____ minutes.
3 to 5
106
The cab of the pumpers will be raised each ____ for in-service units and on each _____ for reserve units.
Monday , Sunday
107
Lowering Cab: Continue to hold the Lower button for ____ seconds after the cab comes to rest on the frame to engage the Cab Locks.
5
108
Pierce Manual Cab Lowering: Person 2 - locate the ____ knob ( ____ on FDP008, 009, & FDP050), underneath and to the front of the battery box on the officer's side.
red, blue
109
Sutphen Manual Cab Lowering: T or F: Person 2 - locates the pressure release valve, underneath the driver side front bumper.
True
110
Pierce 75' Aerial, FDA050: Aerial Set-up: Make sure the pump is _____, apparatus is stopped, the parking brake is set and transmission is in ____.
disengaged , neutral
111
FDA050 : Set the wheel chocks behind and in front of the OFFICER SIDE FRONT wheel, sparing about ___ inches to prevent them from becoming stuck if the truck lowers onto them.
2
112
Aerial Set-up: Make sure truck in is ____ idle.
low
113
FDA050: Note the bubble level under the left rear compartment and operate the _____ side of the truck first.
low
114
FDA050: Extend the stabilizers fully and lower them until about ____ inches off of the ground.
6
115
FDA050: The ground where the truck is set-up must be capable of supporting ____ psi under each stabilizer.
75
116
FDA050: Operate the LOW side stabilizer until about ___ degrees past level.
2
117
FDA050: Slope more than ____ degrees or grade more than ____ degrees requires ladder repositioning.
3.5 , 5.5
118
FDA050: T or F: When the truck is short jacked, it is not possible to operate the aerial over the short jacked side (without using emergency controls.)
True
119
FDA050: ______foot pedal must be depressed in order to activate ladder controls.
"Dead Man Switch"
120
FDA050: T or F: The ladder tip has a load limit of 750 lbs regardless of whether the ladder waterway is charged or uncharged.
True
121
FDA050: The aerial is to be used in an _______ mode.
UNSUPPORTED
122
Never set the ladder tip on roofs or ledges due to the negative load placed on the aerial.
True
123
A standard firefighter weighs ____ lbs.
250
124
FDA050: There is a hoist bar located in compartment # _____.
3
125
FDA050: T or F: This truck has NO SAFETY FEATURES that will prevent the ladder form contacting and/or crushing the cab or other parts of the truck.
True
126
FDA050: Emergency Hydraulic Power: To activate, the ____, _____, and ______ must all be ON.
battery, ignition, aerial master
127
FDA050: T or F: Truck dose NOT automatically engage high idle like other ladder trucks.
True
128
FDA050: Pinnable Waterway: Aerial Nozzle can be adjusted for placement at the ____ section or at the _____ of the ladder.
fly , middle
129
FDA050: To operate the pinnable waterway, the aerial must be ______.
fully retracted
130
FDA050: Bedding: Aerial must be fully _______ to be put in the boom support.
retracted
131
FDA050: Once the aerial is lowered into the boom support, operate the lowering control function for approximately _____ more seconds to make sure the aerial will be secure during road travel.
five
132
FDA050: To prevent overheating of the Emergency Pump Unit (EPU), limit it to a _____ minute run time with a _____ minute cool down period.
30 , 30
133
FDA050: The Aerial Discharge Wheel Valve is a _____ inch valve and piping.
5
134
FDA050: When another pumper/engine is to be supplying water to the aerial, this valve must be ______ to keep water from trying to enter the discharge side of the pump.
closed
135
FDA050: Retraction should be done slowly when flowing ____ to _____ gpm and ladder should not be retracted if flowing _____ gpm or more.
50 to 1000 , 1000
136
FDA050: The rear intake is used only to supply the aerial waterway.
True
137
FDA050: The rear intake must only be supplied from a _____ source (engine/pumper), NEVER directly from a hydrant.
pressurized
138
FDA050: Station setting for the Aerial Main Drain is ______.
CLOSED
139
FDA050: Waterway Relief Valve is located at the rear. It is set to drip at _____ psi and drain at _____ psi.
220 , 250
140
FDA050: Pump Panel Drains are _____ inch piping.
3/4
141
FDA050: Generator: PTO driven and can be engaged anytime, even while driving.
True
142
FDA050: Gauge should be watched to make sure the frequency and MHz do not exceed ____.
60
143
If air pressure drops below ____ psi, the front wheel lock (brake) will engage.
60
144
FDA051: Start-Up Procedures: Move the ignition switch down ___ positions to activate.
2
145
FDA051: Set the wheel chocks behind and in front of the DRIVER SIDE REAR wheel, sparring about ____ inches to prevent them from getting stuck if the truck lowered onto them.
2
146
FDA051: Extend the stabilizers fully and lower them until about ____ inches off the ground.
6
147
FDA051: Before anyone can climb the ladder, three safety checks must be confirmed:
1. One operator must be stationed at the ladder controls. 2. Personnel climbing the ladder must be wearing a ladder belt. 3. Ladder rungs must be aligned.
148
FDA051: The aerial has a load limit of _____ lbs if the ladder pipe is dry. If it is charged, the load is cut to ____ lbs.
1000 , 750
149
FDA051: The aerial is to be used in an _______ mode.
UNSUPPORTED
150
FDA051 is not equipped with tip controls.
True
151
FDA051: Aerial must only be raised while in the ____ support.
boom
152
FDA051: High idle maintains _____ RPM's.
1000
153
Rungs should always be aligned when someone is preparing to climb the ladder.
True
154
FDA051: Be sure to activate the ______ and remove safety pins prior to raising the stabilizers.
Jack Release
155
FDA051: To prevent overheating of the EPU, limit it to a ____ minute run time.
10
156
EPU will not shut down automatically.
True
157
FDA051: Aerial waterway is heavy duty aluminum tubing. Lower sections are ____ inch piping expanding to ___ inch at the fourth section (tip).
3 1/2 , 5
158
FDA051: Retraction should be done slowly when flowing ____ to ____ gpm and ladder should not be retracted if flowing _____ gpm or more.
500 to 1000 , 1000
159
FDA051: Waterway Drain should always be opened after aerial waterway use, ____ retracting the ladder.
before
160
FDA051: Primer is air activated.
True
161
FDA051: DPF (Diesel Particulate Filter)
True
162
FDA051: The regeneration will take approximately ___ to ___ minutes.
20 to 40
163
FDA051: Cab must be lifted to check power steering fluid and coolant.
True
164
FDA051: ALWAYS open the door of the generator compartment when generator is in use to prevent overeating.
True
165
FDA052: Aerial Set-Up: DO NOT engage PTO when rpm are above _____.
1100
166
FDA052: Set wheel chocks on driver side ______ rear wheel.
FORWARD
167
FDA052: Lower both riggers until approximately ___ to ____ inches off the ground.
6-8
168
FDA052: Deploy low-side stabilizer to approximately ____ degrees past center.
2
169
FDA052: Aerial Set-Up: The front tires should be ____ inch off the ground.
1/2
170
FDA052: Slope more than ____ degrees or grade more than ____ degrees requires ladder repositioning.
5 , 20
171
FDA052: It is recommended to turn the UPPER POWER switch ____ during climbing or while exiting the platform to prevent accidental operation of the boom.
off
172
FDA052: Alarm will sound when rotating aerial until ladder clears ___ degrees over the rear of apparatus and ___ degrees over the cab section.
10 , 20
173
FDA052: To operate the aerial at all while short jacked, the ________ button must be pressed simultaneously at the aerial control panel and turntable while raising the aerial out of the bed.
INTERLOCK OVERRIDE
174
Before anyone can climb the ladder, three safety checks must be confirmed:
1. One operator must be stationed at the turntable. 2. Personnel climbing the ladder must be wearing a ladder belt. 3. Ladder rungs must be aligned
175
FDA052: The ladder tip has a load limit of _____ lbs uncharged and _____ charged.
1000, 500
176
FDA052: The stokes has a capacity of ____ lbs per pair.
400
177
FDA052: Max of ____ lbs in platform when using stokes arms.
500
178
FDA052: Rescue lifting shackle has a ____ lbs max.
800
179
FDA052: On-Board Breathing Air: K tank with ____ psi. Station setting for the regulator is ___ psi.
4500 , 70
180
FDA052: Fill attachment to On-Board Air: First low air alarms at ____ psi. Second low air alarms at ___ psi.
900 , 300
181
FDA052: Auxiliary Hydraulic Pump: To activate, the ignition and ______ must all be ON.
Ladder/jack PTO
182
FDA052: Turntable controls override platform controls.
True
183
FDA052: Water system is rated for up to ______ gpm's.
2000
184
FDA052: The water curtain disperses at ____ gpm.
75
185
FDA052: Aerial must be fully _____ to be put in the boom support.
retracted
186
FDA052: Operation of the Auxillary Hydraulic Motor should not exceed ____ minutes without allowing ___ minutes to cool.
2 , 5
187
FDA052: HIGH IDLE will not engage while pump is i gear.
True
188
FDA052: Retraction should be done slowly when flowing ___ to ___ gpm and ladder should not be retracted if flowing ____ gpm or more.
500 to 1000, 1000
189
FDA052: Aerial Main Drain: It is ___ inch piping and should always be opened AFTER aerial waterway use, before retracting the ladder.
2
190
FDA052: Station setting for Aerial Main Drain is _____.
OPEN
191
FDA052: Primer is ____ actuated.
air
192
FDA052: Pump Panel Drains are ____ inch piping.
3/4
193
FDA052: Gauge should be watched to make sure the frequency and MHz do not exceed ____.
60
194
FDA052: Once the generator reaches ____ degrees Farenheit, it shuts down.
180
195
FDA052: The cord reels are each ____ feet long and provide 120v.
200
196
FDA052: To cancel a parked regeneration, hold the DPF switch to the ON position for ____ seconds and release.
5
197
FDT:017 Do not depress the accelerator prior to starting!
True
198
FDT017: If the engine does not start within ___ seconds, release the key - wait ___ seconds - and try again.
5 , 10
199
FDT017: If the engine does not start after ____ attempts, turn off the key and wait approximately ___ minutes.
two, 2
200
FDT017: Starting the Pump Engine: If the engine does not start within ____ seconds, release the starter and wait ___ seconds before trying again.
15 , 60
201
FDT017: Foam Operations: Maximum operation pressure is ____ psi.
500
202
FDT017: Turn the _____ to the Foam position.
selector valve
203
FDT017: Refill Operations Foam: Turn the Percentage Selector Valve to ___.
1.0
204
FDT017: Refill Operations Foam: The refill operation should take approximately ___ minutes.
2
205
FDT017: The winch on this vehicle is electrically operated and requires NO shifting of gears inside the cab.
True
206
FDT017: Disengage 4-Wheel Drive: Place the truck transmission in REVERSE and back the truck up a minimum of ___ feet. You must manually unlock the hubs.
10
207
At start-up, pump _____ psi unless otherwise directed by the source pumped operator.
100
208
FDT017: Use ____ - wheel drive when driving on paved or extremely hard surfaces.
2
209
FDA050: Max wind speed Go/No Go:
35 mph
210
FDA051: Max wind speed Go/No Go:
Sustained 35 mph, Gusts of 50 mph
211
FDA052: Max wind speed Go/No Go:
Sustained 35 mph, Gusts of 50 mph
212
FPD001, FDP005-FDP007: Gross Vehicle Weight:
42,740 lbs
213
FDP001, FDP005-FDP007: Overall Length:
30 feet
214
FDP001, FDP005-FDP007: Overall Width:
8 feet
215
FDP001, FDP005-FDP007: Road Clearance Height:
10 ft 5 in
216
FDP001, FDP005-FDP007: ___ feet of 4-inch LDH
1000
217
FDP001, FDP005-FDP007: ____ feet of 2 1/2 inch
500
218
FDP001, FDP005-FDP007: Wheelbase:
184.5 inches
219
FDP001, FDP005-FDP007: Pump Type:
Hale, 1500 gpm Single Stage
220
FDP001, FDP005-FDP007: Engine:
Detroit Diesel 60 Series, 430 hp
221
FDP001, FDP005-FDP007: Manual Pump Engagement:
NONE
222
FDP001, FDP005-FDP007: Auxiliary Brake:
Jake Brake
223
FDP008-FDP009: Engine:
Detroit Diesel 60 Series, 455 hp
224
FDP008-FDP009: Manual Pump Engagement:
Compartment #1, bottom left-hand corner
225
FDP008-FDP009: Groos Vehicle Weight:
50,500 lbs
226
FDP008-FDP009: Overall Length:
31 feet
227
FDP008-FDP009: Overall Width:
8 ft 2 in
228
FDP008-FDP009: Wheelbase:
173.5 inches
229
FDP10-FDP13: Engine:
Cummins ISL, 450 hp
230
FDP10-FDP13: Booster Tank Capacity:
750 gallons
231
FDP10-FDP13: Gross Vehicle Weight:
42,000 lbs
232
FDP10-FDP13: Overall Length:
33 feet
233
FDP10-FDP13: Overall Width:
10 ft 9 inches
234
FDP10-FDP13: Wheelbase:
196 inches
235
FDP10-FDP13: Road Clearance Height:
10 feet 2 inches
236
FDP10-FDP13: 2 dead loads of _____ ft 2 1/2'
300
237
FDA50: Ladder Height:
75' ft
238
FDA50: Horsepower:
515
239
FDA50: Booster Tank Capacity:
475 gallons
240
FDA050: Gross Vehicle Weight:
53,800 lbs
241
FDA050: Overall Length:
36 ft 4 in
242
FDA050 Overall Width:
8 ft 6 in
243
FDA050: Width of Outriggers Fully Extended:
17 ft 3 in
244
FDA050 has 1,000 ft of 4 INCH LDH!!
True
245
FDA051: Horsepower:
515
246
FDA051: Booster Tank Capacity:
470 gallons
247
FDA051: Gross Vehicle Weight:
54,000 lbs
248
FDA051: Overall Length:
40 feet 5 inches
249
FDA051: Overall Width:
8 ft 2 in
250
FDA051 Wheelbase:
232 inches
251
FDA051: Road Clearance Height:
10 ft 10 in
252
FDA051: Width of Outriggers Fully Extended:
16 feet
253
FDA051: ___ feet of 2 1/2' hose
500
254
Winch Operations: Insert the plug end from the remote control into the receptacle on the ____ side of the winch.
left
256
Winch Operations: Once operations are complete, return the clutch lever to the ___ position, rewind the excess cable and secure the hook.
OUT
257
The tool box on Foam 2 contains a Hydro-Foam ___ gpm fog nozzle.
350
258
The tool box on Foam 2 contains a Blitz Fire Ground Oscillating Master Stream with a __ inch Aspirating Tip.
2"
259
The tool box on Foam 2 contains ___ 1 1/2" fog nozzles with foam tubes attached.
2
260
Truck should be in an area clear of all trees, buildings, vehicles and people during regen due to the very high exhaust temperatures (_____ degrees or more.)
1200