Incore Instruments Flashcards
(13 cards)
Two systems that make up in core instruments
Core exit thermocouples
Movable incore detection system
What are funtions we use MIDS?
Verify heat flux hot channel factor & nuclear enthalpy rise hot channel factor within T.S.
Calibrate excore NI’s for AFD
Verify rod positions when DRPI inoperable
Verify QPTR in spec w/ various sys inop
Describe CET
65 (33, train A/ 32, train B)
Max range- 2300 deg
Two types (protruding-flow mixer, butt type-no mixer)
Two dissimilar metals(alumel, chrome) with hot junction and known cold reference junction
Describe the Mids ?
6 incore fission chambers 6 drive units 6 five paths 6 safety limit switches 6 withdrawal limit switches 6 ten paths
58 isolation vlvs, compression Seals, possible locations
1 storage area
What interlock associated with leak in mids ?
If leak shows level in ten path, get a leak alarm, solenoid valve drains to RCDT
What must be verified before allowing personnel in CNMT?
Mids stored, key not checked out since last stored
Describe AFD/ AI
Top - bottom (PR Ni’s)=> + AI more power in top of core, - AI more power in bottom of core
AI +2 => top = 51%, bot = 49% @ 100% total power
What are indication of failed PR Ni, upper detector (failed high)?
Channel ……
AI….
Drawer…..
Channel fail - high AI fail - high * Total - high, upper - high *, lower - normal Channel deviation alarm QPTR alarm * Detector deviation alarm * PR Rod stop Rod movement demand (until dev > 10%) * half channel failure
Indications of failed high PR Ni ( lower)?
Power…..
AI…..
Drawer…..
Power - high AI - low* Drawer (top - norm, bot - high *, tot - high) Channel deviation alarm PR Rod stop Rod Control insertion demand (until dev > 10%) QPTR alarm* Detector deviation alarm*
Indication of PR Ni upper detector failing low?Channel……
AI……
Drawer……
Channel - low AI - low* Drawer (top- low*, bot - norm, total low) QPTR alarm* Detector deviation alarm* Channel deviation alarm
Indications of PR Ni detector ( lower) failing low?
Channel……
AI…….
Drawer……
Channel - low AI - high* Drawer - (top - norm, bot - low*, total - low) Channel deviation alarm Detector deviation alarm* QPTR alarm*
Functions & controls of miscellaneous Control and indication Drawer
- compare all PR chnls to each other and generate alarm if any differs > 2% from average (if Prx > 50%)
- controls to bypass
- upper channel bypass qptr alarm
- lower channel bypass qptr alarm
- bypass up to 2 channels PR Rod stop (C-2)
- bypass up to 2 channels power mismatch …..
Purpose of Comparator and Rate drawer?
Compares all PR channels and if any > 4% above lowest channel = alarm
- switch to defeat one Channel if failure present
Calculates SUR
- switch to select which channel to use for SUR