Leap-1A - 74 & 80 Flashcards

(8 cards)

1
Q

What supply of air is used to cool the ignition system?

A

VBV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the maximum depth of the tip electrode?

A

6.25 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the failsafe position of the SAV?

A

Closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What variables does the adaptive start depend on?

A
  • OAT
  • Core or nacelle temperature
  • Time since shutdown
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How is adaptive start indicated?

A

COOLING flashes in green on ECAM SD with a countdown timer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Describe a normal automatic start?

A
  1. ENG MASTER ON - LPSOV & SAV open
  2. N2 15% - IGN start
  3. N2 20% - FMV & HPSOV open
  4. N2 55% - IGN stop
  5. N2 60% - SAV closed
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Under what conditions should a manual start be aborted?

A
  • If starting takes longer than 15 seconds
  • If EGT > 725°C
  • If stabilised oil < 17 psi
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the starter duty cycles?

A
  1. 3 consecutive cycles (2 minutes each) with a 60 second rest between each, 15 minutes before repeating
  2. 5 minute cycle, 5 minute rest, 5 minute cycle, 10 minute rest
  3. 15 minute cycle, 15 minute cooling period (borescope only)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly