OQ-0001 Measure Structure To Electrolyte Potential Flashcards

(35 cards)

1
Q

What are methods of corrosion control?

A

Cathartic protection
Protective coatings/wrap

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the 2 types of cathodic protection (CP)?

A

Sacrificial Anodes

Impressed Current ( Rectifier)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the definition of an anode?

A

An electrically conductive material which discharges current into the ground to provide CP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Magnesium anodes are attached to blank

A

Steel pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

CP rates will be taken when?

A

Steel pipe is exposed (except vacuum excavation)

Coating is removed

Coating show signs of deterioration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When is CP reading not required?

A

When the pipeline has been vacuum exposed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

For steel risers when using the voltmeter what do you do with the voltmeter

A

You go over the pipe at the riser , approximately 12” away from the riser

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

For pipeline mains and isolated services what do you do when using the voltmeter ?

A

Go over the pipe from anode locations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What do you do when trying to take reads with the voltmeter in dry conditions?

A

Wet soil around the cell

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where do you connect the single lead from the voltmeter?

A

To the structure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When using the voltmeter you measure the pipe to blank blank

A

Soil potential

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where do you use the multimeter when there is a pipeline main and isolated steel services?

A

Over the pipe away from the anode locations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Where do you use the multimeter when there is an isolated steeel riser ?

A

Over the pipe at the riser , approximately 12” away from the riser

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When using the multimeter in dry conditions what do you do?

A

Wet soil around the cell

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Where do you connect the positive lead from the voltmeter to?

A

The structure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Where do you connect the negative lead from the voltmeter to?

A

Reference cell

17
Q

When using the multimeter you measure the blank to blank potential

18
Q

True or false - the pipe to soil read will be negative when connected as described for both types of meters

19
Q

If the pipe to soil read is positive or no sign who do you contact?

A

Contact technical services ( corrosion control)

20
Q

When you document/record the pipe to soil read what do you document/record?

A

Three (3) places to the right of the decimal point ( example -.095 V)

21
Q

What is Adequate pipe to soil reads?

A

-0.850 volts to -2.500 volts

22
Q

What does wrt mean ?

A

With respect to

23
Q

What is inadequate pipe to soil reads?

A

-0.200 to -0.849 volts

24
Q

When you measure p/s both sides of insulator with what?

A

1/2 cell in same position

25
If the potential difference is blank insulator OK- install anode ( if qualified)
> 100 mV
26
If the potential difference is blank contact tech services ( corrosion control)
< 100 mV
27
If the voltage readings Cannot be corrected by installing the anode who do you contact?
Contact tech services ( Corrosion Control)
28
If the read is -0.199 and more positive voltages are happening what do you do?
Check the connections of the CP measuring device and / or Ensure the soil and moisture levels of the soil he reference cell is grounded to are adequate
29
If the voltage readings Cannot be corrected what do you do?
Contact tech services ( corrosion control)
30
If pipe to soil voltage potentials more negative then -2.500 volts what do you do ?
Contact tech services ( corrosion control)
31
Is a leak a UOC?
No it’s an AOC
32
Is a positive pipe to soil read a UOC?
No it’s an aoc
33
Is atmospheric corrosion a UOC?
Yes
34
Is unprotected steel pipe a UOC?
Yes
35
Is unacceptable pipe to soil trades UOC?
Yes