SOP's 300 Series Flashcards

(45 cards)

1
Q

303.03 What are the 4 parts to the Scott Air Pak NxG2?

A
  1. Cylinder and valve assembly
  2. Back frame and harness
  3. Ez flo or EZ flo II regulator
  4. AV 3000 face piece
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

303.05 What are the three ways to don an SCBA?

A
  1. Seated method
  2. Overhead method
  3. Coat method
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

303.06 What 3 alarms are on the pass device?

A

Pre alarm
Full alarm
Manual alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How many batteries and what type does the SCBA take?

A

3 c batteries

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many pumps of Scott Wash is recommended for cleaning the SCBA regulator and how long should it be left?

A

6 pumps and 10 min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

303.10 How many pumps of Scott wash are recommended for the face mask?

A

3 pumps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What oil besides bar oil can we use for lubing the chain on a chainsaw?

A

30wt

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the oil to gas ratio for a MFD chainsaws?

A

50 to 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What criteria is used before replacing a chainsaw blade?

A
  1. Missing/damaged tips on 3 or more in a row.
  2. Missing/damaged tips on 6 or more
  3. Cracked/broken tie straps.
  4. Dull chain.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What 3 types of circular saws are used by MFD?

A

Partner, K-12, Husqvarna

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What type of blades does MFD use on the circular saw?,

A

Extra high speed blades only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

304.03 How many cfms can an electrically powered Smoke ejector push

A

5200cfm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

304.03 How many watts and amps does it take to start an electric Smoke Ejector?,

A

1500 - 2000 watts and 30-35 amps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

304.03 What size gas smoke ejectors does MFD use?

A

18, 20, and 26

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

304.03 What type of oil is suggested for smoke ejector motor?

A

10w40

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

304.04 What are the specs on the Holmatro spreader?

A

23000lbs of spreading force

weighs 41lbs

squeezing force of 9700lbs

27 inch spread

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

304.04 What are the specs of the Holmatro cutter?

A

5 in cutter
63400lbs cutting force
Weighs 27.5 lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

304.04 What are the specs of the RAM?

A

pushing power of 22400lbs
extends to 43 3/8 inches
weighs 36.5lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What is the max thickness for the cutters to cut?

A

4mm or 5/32 of an inch

20
Q

304.05 What should each Ajax tool kit include?

A

air chisel, pry bar, four chisels, quarter-inch air hose, oil and regulator.

21
Q

What is the safety regulator for the Ajax tool set at?

22
Q

304.05 What is the normal operating PSI for the AJAX tool?

A

90-160 PSI with a max of 300 PSI

23
Q

304.06 Where are Heat Scanners located?

A

in each BC vehicle

24
Q

304.06 How do Heat sensors work?

A

senses infrared energy

25
304.08 What type of aluminum is used in MFD ladders?
Heat treated alloy
26
304.09 "Fly out" use of MFD ladders is in compliance with what NFPA standard?
1932
27
How many FF are allowed on a 19ft ladder?
of FF = the first number on the ladder length 19ft=1 20ft=2 30ft=3
28
304.11 How wide is an attic ladder?
12 3/4 inches.
29
304.11 What size and how many rungs are on an attic ladder?
9ft and 10ft ladders with 14 rungs
30
304.12 What are lengths of the straight ladders used by MFD
14, 16, and 20ft
31
304.13 What type of rope does the MFD prefer for its life lines?
3 stranded Nylon
32
304.13 How many much can a life line hold?
600lbs or 2 FF
33
304.15 What are the five basic knots used in Fire fighting?,
Clove hitch Bowline Becket bend Figure 8 Rescue harness
34
304.16 What is max lift capacity of the airbags used by MFD?
146,000lbs
35
304.16 What PSI is need to inflate the airbags?
118psi
36
304.16 How much lift can 2 airbags give stacked on top of each other?
40 inches
37
305.06 What is the pump intake relief valve set at?
150 PSI
38
305.06 Pump residual pressure can be no less than...?
20psi
39
305,07 What is the GPM per sprinkler head?
90 gpm
40
306.03 What is the standard bumper load and the recommended bumper load length?
Standard=100ft Recommended=150ft
41
Who makes the decision for the length of the bumper load?
Captains decision
42
Max MPH for a forward lay?
10mph
43
309.14 How far from the door should a fan be placed? What angle should the fan be placed?
6ft from the door and 20-30 degree angle
44
What is the equation for PDP?
PDP= np+fl+AP+ EL
45
What is the equation for Friction Loss?
FL= 2(Qsq)xFFxL/100