TB Tools Flashcards
Water Extinguisher shall be hydro-statically tested
Finger over nozzle of extinguisher used only at _
At 5 Year intervals or anytime evidence of corrosion or mechanical damage
Very small or smoldering fires where there’s NO detectable thermal draft
Can Water extinguisher be used at energized electrical fires
Water extinguisher inspected
What if hydrostatic test date is greater than 5 years
Never
Daily & after each use
OOS
KO Curtain inspected
OOD shall contact _ for replacement KO
Can KO Curtain be used for drills
Weekly during MUD & after each use
Admin Division
Under NO Circumstances. Use only Training KO Curtain
How many windows can Fire Window Blanket cover
Which Unit shall deploy Fire Window Blanket
At least 2 if necessary. Bottom weighted to help positioning
Any Unit w/a Spotter observing from exterior
Which members shall be on the floor below to secure Fire Window Blanket
Can Fire Window Blanket be lowered from 2 floors above
The Officer of deploying unit will assign members to floor below
Yes due to lengths of straps
If a Replacement Fire Window Blanket needed- contact _
Can Fire Window Blanket be used for drilling purposes
Tech Services
Under NO circumstances. Use Training Window Blanket only
Fire Window Blanket inspected _
While inspecting Fire Window Blanket you notice that the aluminized foil is peeling & separating from the white cloth. What is done
Weekly during MUD & after use
OOS - Officer shall notify R&D. They will inspect
Combo SS/Fog devices shall be placed in _ position at all times when stored on rig
Aquastream Master stream noz is preset to _ degree fog pattern
Straight stream (turned to right)
130 degree fog pattern. Do NOT use at Con Ed Superstations
If the lights fail to illuminate when power is applied to Portable Lighting & Generating Equipment- what is done
Check bulb for proper connection. If this fails, replace with a new bulb. If still fails- entire light assembly sent to Tech Services for repair (Bulb replacement is only maintenance req’d)
If portable generator used to power an exhaust fan- the ideal length of cord should be _
50’/less. Distance not a problem when powering small tools & lights
Operate Portable Generators for _ minutes weekly. Operate all lights for _ minutes
Waterproof connection for Portable Generators are good for use in up to _’
15; 5
3’ of water
Identifying letters & numbers placed on nozzles & components shall be stamped on
Controlling nozzles will be tested _
Coupling along the hub, adjacent to coupling lug
Annually in August & when deemed necessary by Div Cmdr
FT-1 Tip delivering a flow of approx _ GPM is considered acceptable FF stream
Supplying 1 3/4” HL at no time shall pump pressure exceed _ psi
180 GPM & requires 2 FF’s to handle
250 PSI
FT-2 tip: If you can place your index finger into the bore, the tip is in the _ position
Every 10-77 will have at least _ HRN equipped Eng
Straight stream position
1 Hi Rise Noz Eng (every Battalion has at least one Eng assigned a HRZ)
If 4th Eng NOT equipped w/HRN, Off shall _
Contact Dispatcher to ID Eng equipped w/HRN assigned to the box
When would HRN be used:
IC determines direct interior attack is NOT possible,
Fire apt inaccessible to outside streams, &
IC determines it will be beneficial
HRN is _’ long w/_degree bend
HRN checked
8’ long w/68 degree two foot bend
Weekly during MUD & before use
HRN produces flows of _ at 50 psi noz pressure.
3 lengths 2 1/2” require pressure at outlet gauge of _ psi;
4 lengths require _ psi
200-225 GPM;
70 PSI 3 lengths;
80 PSI 4 lengths
Putting HRN into operation will require 2 Eng companies equipped with _
Is it necessary to remove windows to operate HRN
Rabbit tool, FE tools, HRN, Roll ups, Standpipe kit
Most cases it’s NOT necessary. Window bars & child gates must be removed
Who shall Off of HRN communicate w/to ensure HRN is being operated efficiently
Spotter operating from exterior of bldg
If multiple rooms are involved what is done w/HRN
Start w/window that wind is blowing into & extinguish fire in this room 1st. Then move to other windows downwind of original fire room
HRN repositioning process:
Supply line shut down at shut off 1 length back from noz. Noz opened & bled. Once in position, Off will order water started. Off then notifies IC. IC MUST give approval to open HRN
_ blades will cut through gravel & tar covered roofs, wood flooring, light sheet metal, & similar material.
Carbide tip (Do NOT use on metal security doors, auto bodies, metal window bars & case hardened locks)
_ blades will cut through steel- auto bodies, metal security doors, metal window bars, etc
_ will cut through concrete & masonry material
Aluminum oxide
Silicon Carbide blades