General Regulations and OSHA Safety Review Flashcards
Review general plumbing regulations and compliance requirements. (35 cards)
True or False:
The Authority Having Jurisdiction has discretionary powers to permit deviations from the code requirements in existing buildings that are being renovated or repaired.
True
Fill in the blank:
An alternative engineered design shall provide ______ level of quality, strength, effectiveness, fire resistance and durability.
an equivalent
True or False:
Plumbing fixtures and drains that receive liquid wastes or sewage do not necessarily have to be connected to the drainage system of the building.
False
True or False:
Sewage or other waste water capable of being deleterious to surface or subsurface waters is permitted to be discharged into outdoor ground or water ways without being rendered by an acceptable form of treatment.
False
Fill in the blank:
Burred ends of pipe and tubing shall be ______ to the full bore of the pipe or tube and chips shall be removed.
reamed
True or False:
Waste connections are permitted to be made to a closet bend.
False
True or False:
Enlargement of 3” closet bend or stub to 4” shall be considered an obstruction of the pipe.
False
Fill in the blank:
Every building shall have ______ connection(s) with a public or private sewer.
an independent
Fill in the blank:
Protectively coated pipe shall be ______ and visible damage shall be repaired.
inspected
Fill in the blank:
Pipes that penetrate through an exterior wall or roof shall be made ______.
watertight
Fill in the blank:
Plastic and copper piping penetrating frame members within ______ of the exposed framing shall be protected by steel nail plates.
1 inch
Fill in the blank:
A structural member weakened or impaired by cutting or notching shall be ______.
repaired
Fill in the blank:
Piping shall be supported in such a manner as to maintain its ______ and prevent sagging.
alignment
Fill in the blank:
Gas piping shall be supported by ______ straps or hooks.
metal
True or False:
An open trench may be buried prior to testing and inspection.
False
True or False:
Food or drink shall be permitted to be stored, prepared or displayed beneath soil or drain pipes without additional provisions for leakage or condensation from such pipes.
False
Fill in the blank:
Test gauges shall have a pressure range not exceeding ______.
twice the test pressure applied
What is the maximum horizontal distance between supports for Cast Compressed Gasket pipe where joints are less than 4 feet apart?
every other joint
What is the maximum horizontal distance between supports for 1” copper pipe?
6 feet
What is the maximum horizontal distance between supports for 1 1/2” Threaded Steel pipe for DWV?
12 feet
What is the maximum horizontal distance between supports for 3/4” PEX pipe?
32 inches
What is the maximum horizontal distance between supports for 1 1/2” PEX pipe?
48 inches
What is the maximum horizontal distance between supports for 1” Polypropylene pipe?
32 inches
What is the maximum vertical distance between supports for PEX pipe?
base and each floor