General Regulations and OSHA Safety Review Flashcards

Review general plumbing regulations and compliance requirements. (35 cards)

23
Q

True or False:

The Authority Having Jurisdiction has discretionary powers to permit deviations from the code requirements in existing buildings that are being renovated or repaired.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Fill in the blank:

An alternative engineered design shall provide ______ level of quality, strength, effectiveness, fire resistance and durability.

A

an equivalent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

True or False:

Plumbing fixtures and drains that receive liquid wastes or sewage do not necessarily have to be connected to the drainage system of the building.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

True or False:

Sewage or other waste water capable of being deleterious to surface or subsurface waters is permitted to be discharged into outdoor ground or water ways without being rendered by an acceptable form of treatment.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

Fill in the blank:

Burred ends of pipe and tubing shall be ______ to the full bore of the pipe or tube and chips shall be removed.

A

reamed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

True or False:

Waste connections are permitted to be made to a closet bend.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

True or False:

Enlargement of 3” closet bend or stub to 4” shall be considered an obstruction of the pipe.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

Fill in the blank:

Every building shall have ______ connection(s) with a public or private sewer.

A

an independent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

Fill in the blank:

Protectively coated pipe shall be ______ and visible damage shall be repaired.

A

inspected

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

Fill in the blank:

Pipes that penetrate through an exterior wall or roof shall be made ______.

A

watertight

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

Fill in the blank:

Plastic and copper piping penetrating frame members within ______ of the exposed framing shall be protected by steel nail plates.

A

1 inch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

Fill in the blank:

A structural member weakened or impaired by cutting or notching shall be ______.

A

repaired

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

Fill in the blank:

Piping shall be supported in such a manner as to maintain its ______ and prevent sagging.

A

alignment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

Fill in the blank:

Gas piping shall be supported by ______ straps or hooks.

A

metal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

True or False:

An open trench may be buried prior to testing and inspection.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

True or False:

Food or drink shall be permitted to be stored, prepared or displayed beneath soil or drain pipes without additional provisions for leakage or condensation from such pipes.

39
Q

Fill in the blank:

Test gauges shall have a pressure range not exceeding ______.

A

twice the test pressure applied

40
Q

What is the maximum horizontal distance between supports for Cast Compressed Gasket pipe where joints are less than 4 feet apart?

A

every other joint

41
Q

What is the maximum horizontal distance between supports for 1” copper pipe?

42
Q

What is the maximum horizontal distance between supports for 1 1/2” Threaded Steel pipe for DWV?

43
Q

What is the maximum horizontal distance between supports for 3/4” PEX pipe?

44
Q

What is the maximum horizontal distance between supports for 1 1/2” PEX pipe?

45
Q

What is the maximum horizontal distance between supports for 1” Polypropylene pipe?

46
Q

What is the maximum vertical distance between supports for PEX pipe?

A

base and each floor

47
# True or False: Support hangers for piping are permitted to be placed on the coupling.
False
48
# Fill in the blank: The spoil pile and other materials for a trench excavation should be kept at least \_\_\_\_\_\_ feet from the edge of the trench.
2
49
What is the maximum that a 10-foot plank should extend past a support?
12”
50
# Fill in the blank: Scaffold components are required to handle \_\_\_\_\_\_ times the indented weight load.
four
51
What is the minimum spacing between ladder rungs on a step ladder?
10”
52
What is the basic required height for a midgard rail on a platform or scaffold?
21”
53
# Fill in the blank: Shoring is required when work is being performed in a trench that is \_\_\_\_\_\_ feet in depth or more.
5 feet
54
What is the basic required height for an upper guard rail on a platform or scaffold?
42”
55
# True or False: Extension ladders should be secured to the structure at the upper level landing.
True
56
# Fill in the blank: When a trench is \_\_\_\_\_\_ feet or deeper, a means of egress is required.
4’
57
What is the required angle for an extension ladder from the horizontal surface?
75.5 degrees