Practice Test 1 Flashcards
Prepare for the UPC exam with practice tests and review questions. (220 cards)
What size cleanout is required for a 3” pipe?
2 1/2”
What is the size for a horizontal rainwater pipe with a slope of 1/8” per foot with a maximum flow rate of 200 gallons per minute?
6”
Fill in the blank:
A vent terminal for a gas appliance passing through a roof with a slope over 14/12 to 16/12 shall have a minimum height above the roof of ______ feet.
6
Convert:
10.83’ to feet and fractional inches.
10’ 10”
When calculating water supply sizing for public use fixtures, what is the individual fixture unit value for each flushometer valve if there are three water closet valves installed?
20
What is the maximum horizontal distance between supports for 1/2” Threaded Steel pipe for water lines?
10 feet
Fill in the blank:
Sink faucets shall have a maximum flow rate of not more than ______ at 60 psi.
2.2 gpm
Fill in the blank:
When calculating the opening for indoor combustion air on the same story, the dimensions for air openings shall be not less than ______ inches.
3
What is the maximum horizontal spacing between supports for 2” steel gas pipe?
10 feet
Calculate the measurement for O if the spread between pipes is 11” and L is 16”.
20 9/16”
How many test cocks are required on a reduced-pressure principle backflow preventer assembly?
4
What is the fitting that should be installed at point B?
3” x 2” Wye
Find the drop if the grade is 1/8” per foot and the run is 20 feet.
2 1/2”
Fill in the blanks:
The rough gas pipe inspection shall be made ______ gas piping has been installed and ______ the gas piping is covered or concealed.
after, before
Find the grade of a pipe if the drop is 11 1/4” and the run is 90 feet.
1/8” per foot
Fill in the blank:
Outdoor combustion air obtained through one permanent opening method shall have a minimum free area of 1 square inch per ______ BTU/h.
3000
Fill in the blank:
Not more than ______ of the total permitted length of a drainage vent shall be installed in a horizontal position.
one-third
Which is not one of the qualities required for plumbing fixture surfaces?
a. smooth
b. impervious
c. free from concealed fouling surfaces
d. textured
d. textured
Calculate the measurement for a special case 90 degree offset using 45 degree elbows for M if the spread between pipes is 15”.
13 13/16”
Which of the following fixtures in a food and beverage handling establishment does not require an indirect waste connection?
a. freezer
b. hand wash sink
c. steam table
d. hot and cold drink dispenser
b. hand wash sink
Fill in the blank:
Tests requiring a pressure exceeding 10 psi shall be performed with gauges of ______ incrementation or less.
1 psi
Fill in the blank:
Overpressure protection devices shall be installed on gas systems with a system pressure greater than ______ psi which serve appliances designed to operate at 14 inches water column.
2
Fill in the blank:
Where galvanized piping is used for drainage, it shall be kept not less than ______ inches above ground.
6
Fill in the blank:
The total required volume of indoor combustion air shall be ______ the required volume calculated for all appliances located within the space.
the sum of