Sanitary Drainage Systems Flashcards

Learn about sanitary drainage systems and compliance requirements. (45 cards)

1
Q

True or False:

Vitrified clay pipe is approved for use aboveground.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

True or False:

Stainless steel drainage piping shall not be installed underground.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Fill in the blank:

Where stainless steel piping is used for drainage, it shall be kept not less than ______ inches above ground.

A

6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Cast Iron pipe is approved for use in which of the following drainage applications?

a. Underground DWV
b. Above Ground DWV
c. Building Sewer
d. All of the above

A

d. all of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Stainless steel 304 pipe is approved for use in which of the following applications?

a. Underground DWV
b. Above Ground DWV
c. Building Sewer
d. All of the above

A

b. Above Ground DWV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the minimum trap size for a bathtub?

A

1 1/2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the minimum trap size for a domestic kitchen sink?

A

1 1/2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Fill in the blank:

A private bathtub drain has a value of ______ Drainage Fixture Units (DFU).

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Fill in the blank:

A private drinking fountain drain has a value of ______ Drainage Fixture Units (DFU).

A

0.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Fill in the blank:

A private kitchen sink drain has a value of ______ Drainage Fixture Units (DFU).

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Fill in the blank:

A public commercial food waste disposer drain has a value of ______ Drainage Fixture Units (DFU).

A

3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the minimum trap size for an indirect waste receptor that receives liquid waste from heavy demand commercial sinks or dishwashers?

A

2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the maximum drainage fixture unit value for a 3” trap and trap arm?

A

6 DFU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the drainage fixture unit value for an intermittent flow of 8 GPM?

A

2 DFU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the maximum number of drainage fixture units for a 4” vertical drainage pipe?

A

256

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the maximum vertical developed length in feet for a 3” horizontal drainage pipe?

A

212

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What are the maximum drainage fixture units that can be served by a 1 1/2” vent pipe?

A

8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is the maximum developed length for a 1 1/2” drainage vent pipe?

A

60 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What is the maximum developed length for a 2” drainage vent pipe?

20
Q

True or False:

A floor drain is required to be installed adjacent to a commercial sink.

21
Q

Fill in the blank:

Cast-Iron caulked joints shall be packed with oakum and filled with molten lead to a depth of not less than ______ in one continuous pour.

22
Q

Which of the following is not an approved method for joining copper drainage pipes?

a. brazed joint
b. mechanical joint
c. soldered joint
d. caulked joint

A

d. caulked joint

23
Q

True or False:

Transition solvent cement joint is permitted to be used between ABS and PVC pipe at the building drain and building sewer connection.

24
Q

Which of the following bends are not listed as an approved fitting for creating a change of direction in drainage piping?

a. one-third bend
b. one-sixth bend
c. one-eighth bend
d. one-sixteenth bend

A

a. one-third bend

25
What size cleanout is required for a 2" pipe?
1 1/2"
26
# Fill in the blank: Cleanout plugs shall have a countersunk \_\_\_\_\_\_ slot.
rectangular
27
Each cleanout shall be installed so that it opens to allow cleaning.
in the direction of flow
28
What is the minimum clearance for a 2" cleanout?
18" x 18”
29
# Fill in the blank: No under-floor cleanout shall be located exceeding \_\_\_\_\_\_ feet from an access door, trap door or crawl hole.
5
30
# Fill in the blank: The required slope for drainage piping that is 4" and larger in diameter is \_\_\_\_\_\_ inch per foot.
1/8
31
What is the minimum diameter drainage pipe for the discharge pipe from a sewage ejector pump serving a single dwelling unit?
2”
32
# True or False: A gate or ball valve shall be located before the check valve on the discharge line from a sewage ejector.
False
33
# Fill in the blank: The lowest inlet into a sewage ejector sump shall have a clearance of not less than \_\_\_\_\_\_ inch(es) from the highwater or "starting" level of the sump.
2
34
# Fill in the blank: A covered sump shall have a vent that is not less than \_\_\_\_\_\_ inches in diameter.
1 1/2
35
# True or False: Plastic pipes shall not be permitted to be tested with air.
True
36
# Fill in the blank: When testing a drainage and vent system using air, the system shall hold pressure for a period of not less than \_\_\_\_\_\_ minutes.
15
37
# Fill in the blank: The public sewer shall be considered as not being available where it is located more than \_\_\_\_\_\_ feet from a proposed building.
200
38
# Fill in the blank: The building sewer shall begin \_\_\_\_\_\_ feet from the building.
2
39
What is the pipe size for a building sewer that is carrying 625 drainage fixture units and has a slope of 1/8" per foot?
8”
40
# Fill in the blank: A building sewer pipe that is 4" in diameter shall be installed at a uniform slope of not less than \_\_\_\_\_\_ inch per foot toward the point of disposal
1/8
41
# Fill in the blank: The building sewer piping shall be laid on a firm bed and supported \_\_\_\_\_\_.
the entire length of the pipe
42
# Fill in the blank: Each cleanout shall be installed so that it \_\_\_\_\_\_.
opens to allow cleaning in the direction of flow
43
What is the minimum horizontal distance required that a building sewer should be away from a building or structure?
2 feet
44
# Fill in the blank: Building sewers that are plastic DWV shall be tested by plugging the end and filling the building sewer with \_\_\_\_\_\_.
water
45
What is the minimum trap size for a clinical sink?
3”