Fill in the blank:
Pipes from fixtures shall be run to the ______.
nearest wall
True or False:
Where a fixture comes in contact with the wall or floor, the joint between shall be made watertight.
True
Fill in the blank:
Wall-hung fixtures shall be rigidly supported by ______ supporting members so that no strain is transmitted to the connections.
metal
Which material is not listed for use as a flanged fixture connection?
a. steel
b. ABS
c. PVC
d. hard lead
a. steel
Fill in the blank:
Water closet bowls shall be set level with an angle of ______ degrees between the floor and wall at the center line.
90
Fill in the blank:
The floor and wall shall have a flat mounting surface not less than ______ inches to the right and left of the fixture outlet centerline.
5
Fill in the blank:
Fixtures shall be installed in accordance with ______.
manufacturer’s installation instructions
Fill in the blank:
An access panel for a slip joint connection shall be no less than ______ inches in its least dimension.
12
True or False:
Wooden sinks for domestic use shall be permitted for installation in buildings used for human habitation.
False
Which material is not a material approved for special use fixtures?
a. soapstone
b. copper-based alloy
c. treated or conditioned wood
d. corrosion-resistant steel
c. treated or conditioned wood
What is the maximum flow rate for a public lavatory faucet at 60 psi?
0.5 gpm
What is the maximum amount of water in gallons to be delivered by a metered faucet per metering cycle?
0.25 gallons
What is the maximum flow rate for a showerhead at 80 psi?
2.5 gpm
What is the minimum waste outlet size for a shower?
2”
Fill in the blank:
A shower dam or threshold shall not be more than ______ above the top of the drain.
9”
Fill in the blank:
Shower compartments shall have a finished interior surface of not less than ______ square inches.
1024
Fill in the blank:
Shower lining materials shall be pitched ______.
1/4” per foot
Fill in the blank:
Control valves and shower heads shall be located on a side wall and shall not discharge ______.
directly at the entrance
Fill in the blank:
The water supply riser for the shower head outlet shall be ______.
securely attached to the structure.
Fill in the blank:
A pump access for a whirlpool tub located in a crawl space shall be located not more than ______ feet from an access door or trap door.
20
True or False:
The circulation piping for a whirlpool tub shall be selfdraining to minimize water retention.
True
Fill in the blank:
Water closet bowls for public use shall be of the ______.
elongated type
Fill in the blank:
Urinals shall have an average water consumption of ______ gallons of water per flush.
1
Fill in the blank:
Where non water urinals are installed, no less than ______ water supply fixture shall be installed upstream on the same drain to facilitate drain flow and rinsing.
1