High Rise Office Bldg Flashcards

(44 cards)

0
Q

What temperature rating should fusible links have above there max temp normally encountered in the system?

A

50 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

How do you place HVAC systems in non circulating mode?

A

Open all outside air supply dampers
Closing all mixing dampers
Open all exhaust dampers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

In a HR office fire can fire spread in the plenum from one floor to another through what?

A

Flexible connectors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What floor would high pressure pumping come into play?

A

31 floor. 31-40= need 300 psi

Starts 1-10 = 150 add 50 every ten floors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When using high pressure hose how far away should the safety zone be? And also around the rig?

A

50 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Can you use regular fitting when using high pressure hose?

A

No white high pressure fittings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When using high pressure pumping where are the supply lines connected on the engine?

A

On the opposite side of the control panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When shall a 10-76 be transmitted?

A

When a report of a fire in a high rise office bldg is confirmed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

At a high rise office bldg when would you give a second alarm?

A

Visible fire OR smoke emanating through the exterior skin of the bldg. Or when a serious fire is confirmed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

At a HR office fire where does the Cfr engine report to?

And what do they bring with them?

A

Report to the fire sector supervisor.

They bring with them all crfd equipment and a set of FE tools

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

At a HR office fire where is the 3 ladder company going to operate?

A

The floor above the fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

At a HR fire where is the 4th ladder company assigned?

A

They operate on the roof than top 5 floors and to initiate the search of the attack stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

At a HR office bldg fire where is the fast truck assigned to?

A

Fire sector supervisor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is considered the fire sector

A

Fire floor and floor above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

At a HR office bldg what is the preferable stair to use as evacuation stair?

A

Stair with fire tower

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

At HR office bldg fires which stair is most important to search?

A

Attack stair

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

At a HR office bldg fire initially which floors need to be evacuated?

A

Fire floor and floor above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

At a HR office bldg fire can the second line be used on the floor above ?

A

No Used on the fire floor to help first line

18
Q

Is ventilation by windows at a HR office bldg fire a initial consideration ?

19
Q

When conditions permit where is the fire sector chief located?

A

One floor below the fire

20
Q

When units are assigned to a branch ( fire sector, SAE etc) they should communicate with who?

A

There sector supervisor unless you have an urgent message than directly to IC

21
Q

When an engine CO is sent to the forward staging area they shall bring what with them?

A

A SCBA for each member
Standpipe kit and nozzle
A length of hose for each firefighter
A spare SCBA for each member

22
Q

What should a ladder CO bring with them when reporting to a forward staging area?

A

A SCBA for each member
2 sets of FE tools and 6 foot hooks
Search and utility ropes
A spare SCBA for each member

23
Q

Can we use Positive Pressure fans in fixed pressurization stairs?

A

No

But we can if there not working or don’t have pressurized stairs

24
When at a HR office fire would we use natural ventilation? Opening the doors at top and bottom of stairs?
When the fire is extinguished
25
When a unit is assigned to Search and Evacuation group what shall they bring with them?
A spare SCBA for each member
26
At a HI rise fire where would you expect to find the search and evacuation group?
A floor not served by an elevator serving the fire floor and at least five floors above the fire
27
You are the fourth ladder co assigned to a hi rise fire you are going to be assigned to the SAE group you would no to be operating on what radio Channel ?
Initially primary tactical than AFTER establishment of SAE group operate on secondary tactical
28
What is the order at a hi rise fire to operate the fire pumps?
K C start the lever | Knife switch. Circuit breaker. Start button. Lever the speed.
29
At a hi rise office bldg fire what is the order of preference for the strategic operating plan?
``` determine the fire floor Verify the fire floor Evacuation simultaneously or as soon as possible Gain Control of bldg systems Confine and extinguish fire ```
30
If your engine company is assigned to be lobby control unit or systems control unit who would you report into other than IC ?
Logistics section chief
31
What is the primary function of the lobby control unit?
Recall control and operate elevators recall and search all elevators terminating at the lobby
32
What's the primary function of the systems control unit?
Control all class E communication system and HVAC and any other system the IC directs
33
Who is responsible to set up the Incident command post at a high rise office bldg fire?
The first officer to arrive
34
At high rise office bldg can we start the fire pumps without first checking the bypass valve?
Yes it is permissible
35
When opening a bypass valve at a fire pump in a hi rids office bldg which way do we turn clockwise or counterclockwise ?
Counterclockwise to open
36
At a fire in a high rise office bldg the bldg fire director should be told to go where and await the chief to arrive?
The lobby to assist the IC
37
Stack effect increases with bldg height and becomes noticeable in bldgs over ____ tall?
60 ft
38
The possibility of NEGATIVE stack effect is greatest when temperature outside is above _____ degrees?
90 degrees
39
The 1968 code for fire pumps requires a manual fire pump be installed in bldgs over how many ft.
300 ft
40
In high rise office bldg the 1938 code requires manual fire pumps to be installed when a bldg is how many ft. High?
250
41
Bypass valves at fire pumps should be in what position open or closed?
Closed position
42
Is there a phone at manual fire pumps that can communicate to IC post?
Yes
43
What pressure should manual fire pumps be to deliver to the highest floor?
50 psi