What powers u-8104 (Emergency Borate Valve)?
→uEB4-1
→Controlled by either MCB or RSP
→no automatic functions
What happens to RMUW on SI?
→VCT outlet valves close after RWST to CCP valves open
→RMUW Pumps stop until SIS or BOS OL clears, restart after ~130 seconds
→Normal heat trace panels load shed
Per the TRM, heat tracing must maintain temperature
Per TRM must maintain piping >65°F
Does FCV-110A fail open or closed?
Fail Open AOV (continue to manual emergency borate)
Control Modes
- Off
- Auto
- Borate
- Dilute
- Alternate Dilute
- Manual
NOTE: control relays powered from PC1, on loss of PC1 system can be manually operated to provide makeup flow.
How does AUTO makeup work?
→makeup starts at 46% VCT level
→makeup stops at 56% VCT level
→total max flow 127 gpm (max in auto)
→aligned to VCT outlet
BAT Tanks
→Useable vol 43,000 gals
→TRM min concentration of 7,000 ppm
→TRM minimum temperature of 65°F
→Room heaters set at 90°F
→Remote and local level and temperature indication, remote indication on U1 only
Boric Acid Transfer Pump power supplies and flow
→X-01: uEB1-1
→X-02: uEB4-1
→75 gpm @ 100 psig
→can be controlled at RSP; no auto position on RSP
How are FK-111 and FK-110 maintained? Auto vs. manual.
→FK-111 and FK-110 maintained in manual
→swap to auto when an auto makeup occurs
→if manual pushbutton is pushed, it will seal in and prevent swap to auto
→to remove the seal-in, push the auto pushbutton
Pot settings and max flow for FK-110
→FK-110 is 10 turn pot to control flow 0-40 gpm
→controls flow from BATs
→27 gpm considered maximum flow
→pot setting is desired flow/4
Pot settings and max flow for 111
→FK-111 is 10 turn pot to control flow 0-160 gpm
→controls makeup flow through blender (RMUW + BA)
→127 gpm hard setpoint for AUTO overrides pot setting
→pot setting is desired flow/16
BA Flow Deviation Alarm
Desired flow is not obtained within ±1 gpm within 25 seconds. If occurs, it closes FCV-110B and FCV-111B.
When a blended flow of a concentration >1600 ppm is desired…
the maximum boric acid flow should NOT be expected to exceed 27 gpm. Therefore, a Manual Blended Makeup is required to achieve boron concentration >1600 ppm.
Emergency Boration Flowpaths
Preferred Emergency Boration
→BAT to BA transfer pump, through u-8104 to suction of CCPs
→75 gpm
Emergency Boration Flowpaths
Manual Emergency Boration
→BAT to BA transfer pump, through FCV-110A, through uCS-8439 to suction of CCPs
→36 gpm
Emergency Boration Flowpaths
Gravity Feed Emergency Boration
→gravity feed from BAT through u-8509 to suction of CCPs
Emergency Boration Flowpaths
Alternate Emergency Boration
→BAT to BA transfer pump, through FCV-110A, through blender, through FCV-110B to suction of CCPs
→27 gpm
BAT and RWST min level (MODES 1-4)
→BAT must be >50%
→RWST must be >95%
→per TR 13.1.31
RMUW Flo Deviation Alarm
Desired flow is not obtained within ± 8 gpm within 25 seconds. If occurs closes FCV-110B and FCV-111B.
(FCV-111B should already be closed in this case since any flow with boron is directed to the bottom of the VCT.)
TR 13.1.31 Boron Injection System Operating (MODES 1-4)
Two OPERABLE paths (2 out of the 3 paths below):
→1 BAT, BA transfer pump or Gravity Feed & CCP
→RWST, Train A RWST Valve, Train A CCP
→RWST, Train B RWST Valve, Train B CCP
Note: Mode 4 - PDP can be sued in place of CCP
TR 13.1.32 Boron Injection Systems Shutdown (MODES 5-6)
One OPERABLE path
If using RWST as borated water source in Modes 5 & 6, required to be operable with:
→minimum level of 24% (15% in Mode 6 with head removed and SIP injection path)
→minimum boron concentration of 2400 ppm
→minimum solution temperature of 40° F
The chem add lineup has an orifice to limit chem add flow to…
→2 gpm
→Used to add chemicals for pH control and O2 scavenging
→RMUW pumps provide driving force
Per ABN-107, Attachment 7, for stuck control rods…
…borate 1800 gallons of 7000 ppm boric acid OR equivalent for EACH control rod not fully inserted.
Which dilution control mode gives the quickest reactivity response?
alternate dilute
(can be aligned to bottom of VCT)