Systems Exam 2 - Reactor Makeup Flashcards

(25 cards)

1
Q

What powers u-8104 (Emergency Borate Valve)?

A

→uEB4-1
→Controlled by either MCB or RSP
→no automatic functions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What happens to RMUW on SI?

A

→VCT outlet valves close after RWST to CCP valves open
→RMUW Pumps stop until SIS or BOS OL clears, restart after ~130 seconds
→Normal heat trace panels load shed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Per the TRM, heat tracing must maintain temperature

A

Per TRM must maintain piping >65°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Does FCV-110A fail open or closed?

A

Fail Open AOV (continue to manual emergency borate)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Control Modes

A
  1. Off
  2. Auto
  3. Borate
  4. Dilute
  5. Alternate Dilute
  6. Manual

NOTE: control relays powered from PC1, on loss of PC1 system can be manually operated to provide makeup flow.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How does AUTO makeup work?

A

→makeup starts at 46% VCT level
→makeup stops at 56% VCT level
→total max flow 127 gpm (max in auto)
→aligned to VCT outlet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

BAT Tanks

A

→Useable vol 43,000 gals
→TRM min concentration of 7,000 ppm
→TRM minimum temperature of 65°F
→Room heaters set at 90°F
→Remote and local level and temperature indication, remote indication on U1 only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Boric Acid Transfer Pump power supplies and flow

A

→X-01: uEB1-1
→X-02: uEB4-1
→75 gpm @ 100 psig
→can be controlled at RSP; no auto position on RSP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How are FK-111 and FK-110 maintained? Auto vs. manual.

A

→FK-111 and FK-110 maintained in manual
→swap to auto when an auto makeup occurs
→if manual pushbutton is pushed, it will seal in and prevent swap to auto
→to remove the seal-in, push the auto pushbutton

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Pot settings and max flow for FK-110

A

→FK-110 is 10 turn pot to control flow 0-40 gpm
→controls flow from BATs
→27 gpm considered maximum flow
→pot setting is desired flow/4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Pot settings and max flow for 111

A

→FK-111 is 10 turn pot to control flow 0-160 gpm
→controls makeup flow through blender (RMUW + BA)
→127 gpm hard setpoint for AUTO overrides pot setting
→pot setting is desired flow/16

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

BA Flow Deviation Alarm

A

Desired flow is not obtained within ±1 gpm within 25 seconds. If occurs, it closes FCV-110B and FCV-111B.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When a blended flow of a concentration >1600 ppm is desired…

A

the maximum boric acid flow should NOT be expected to exceed 27 gpm. Therefore, a Manual Blended Makeup is required to achieve boron concentration >1600 ppm.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Emergency Boration Flowpaths

Preferred Emergency Boration

A

→BAT to BA transfer pump, through u-8104 to suction of CCPs
→75 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Emergency Boration Flowpaths

Manual Emergency Boration

A

→BAT to BA transfer pump, through FCV-110A, through uCS-8439 to suction of CCPs
→36 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Emergency Boration Flowpaths

Gravity Feed Emergency Boration

A

→gravity feed from BAT through u-8509 to suction of CCPs

17
Q

Emergency Boration Flowpaths

Alternate Emergency Boration

A

→BAT to BA transfer pump, through FCV-110A, through blender, through FCV-110B to suction of CCPs
→27 gpm

18
Q

BAT and RWST min level (MODES 1-4)

A

→BAT must be >50%
→RWST must be >95%
→per TR 13.1.31

19
Q

RMUW Flo Deviation Alarm

A

Desired flow is not obtained within ± 8 gpm within 25 seconds. If occurs closes FCV-110B and FCV-111B.

(FCV-111B should already be closed in this case since any flow with boron is directed to the bottom of the VCT.)

20
Q

TR 13.1.31 Boron Injection System Operating (MODES 1-4)

A

Two OPERABLE paths (2 out of the 3 paths below):
→1 BAT, BA transfer pump or Gravity Feed & CCP
→RWST, Train A RWST Valve, Train A CCP
→RWST, Train B RWST Valve, Train B CCP

Note: Mode 4 - PDP can be sued in place of CCP

21
Q

TR 13.1.32 Boron Injection Systems Shutdown (MODES 5-6)

A

One OPERABLE path

If using RWST as borated water source in Modes 5 & 6, required to be operable with:
→minimum level of 24% (15% in Mode 6 with head removed and SIP injection path)
→minimum boron concentration of 2400 ppm
→minimum solution temperature of 40° F

22
Q

The chem add lineup has an orifice to limit chem add flow to…

A

→2 gpm
→Used to add chemicals for pH control and O2 scavenging
→RMUW pumps provide driving force

23
Q

Per ABN-107, Attachment 7, for stuck control rods…

A

…borate 1800 gallons of 7000 ppm boric acid OR equivalent for EACH control rod not fully inserted.

24
Q

Which dilution control mode gives the quickest reactivity response?

A

alternate dilute
(can be aligned to bottom of VCT)

25
How do you calculate boric acid flow for blended flow?
BA Flow x BAT conc = TOTAL Flow x RCS conc