Temperature at which PORVs automatically arm for LTOP
≤350° F
(automatically disarm >350° F)
How many PORVs are required to prevent overpressure?
Only one
A single PORV has adequate relief capability to prevent overpressure if the transient is limited to:
- starting an idle RCP with secondary water temperature
≤ 50°F above RCS CL temperature - the start of 2 charging pumps and their injection into a water solid RCS
TS 3.4.12 requirements for LTOP
→2 RHR suction reliefs (lift @ 450 psig ± 3%), or
→2 PORVs, or
→1 of each
→0 SI pumps capable of injecting
→2 charging pumps capable of injecting
→0 accumulators capable of injecting
If these requirements are not met, then the RCS must be depressurized and a 2.98 sq in vent path must be made in the RCS pressure boundary.
Describe the LTOP circuitry by train
Each train consists of 4 inputs feeding 2 auctioneered low circuits with 1 train providing input into a setpoint generator and the other supplying the permissive to open the opposite train’s PORV.
Train A LTOP Inputs
For PCV-455A:
→T-hot 413A (Loop 1)
→T-hot 423A (Loop 2)
→T-cold 433B (Loop 3)
→T-cold 443B (Loop 4)
→PT-405 (Loop 1 WR pressure)
Temperature arms Train B, but pressure operates Train A
Train B LTOP Inputs
For PCV-456:
→Tcold 413B (Loop 1)
→Tcold 423B (Loop 2)
→T-hot 433A (Loop 3)
→T-hot 443A (Loop 4)
→PT-403 (Loop 4 WR pressure)
Temperature arms Train A, but pressure operates Train B
LTOP is required when any CL temperature is…
(TS 3.4.12)
≤ 320°F
When LTOP is required by TS 3.4.12, the following is also required to ensure no heat transients beyond LTOP capability occur:
- render all SIPs and one charging pump incapable of injection
- close and deactivate SI accumulator discharge valves
- preclude the start of RCPs if secondary water temperature is > 50°F above primary
Per TS 3.4.12, LTOP applies Mode 4, 5, and 6 (when RV head on), but does not apply when all RCS CL temperatures > 320°F and all of the following are met:
- at least 1 RCP operating
- PZR level ≤ 92%
- Plant heatup rate is limited to 60°F per hour
Note: LTOP will still arm ≤350°F
When is LCO 3.0.4.b not applicable regarding LTOP?
When entering MODE 4
Which PORV opens faster on NOP/NOT overpressure? Which PORV opens faster on LTOP actuation?
Overpressure: PCV-455A, due to the PI Controller
LTOP: They open simultaneously
What are the LTOP PORV setpoints for different temperatures?