Systems Exam 2 - LTOP Flashcards

(13 cards)

1
Q

Temperature at which PORVs automatically arm for LTOP

A

≤350° F

(automatically disarm >350° F)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many PORVs are required to prevent overpressure?

A

Only one

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A single PORV has adequate relief capability to prevent overpressure if the transient is limited to:

A
  1. starting an idle RCP with secondary water temperature
    ≤ 50°F above RCS CL temperature
  2. the start of 2 charging pumps and their injection into a water solid RCS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

TS 3.4.12 requirements for LTOP

A

→2 RHR suction reliefs (lift @ 450 psig ± 3%), or
→2 PORVs, or
→1 of each
→0 SI pumps capable of injecting
→2 charging pumps capable of injecting
→0 accumulators capable of injecting

If these requirements are not met, then the RCS must be depressurized and a 2.98 sq in vent path must be made in the RCS pressure boundary.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Describe the LTOP circuitry by train

A

Each train consists of 4 inputs feeding 2 auctioneered low circuits with 1 train providing input into a setpoint generator and the other supplying the permissive to open the opposite train’s PORV.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Train A LTOP Inputs

A

For PCV-455A:
→T-hot 413A (Loop 1)
→T-hot 423A (Loop 2)
→T-cold 433B (Loop 3)
→T-cold 443B (Loop 4)
→PT-405 (Loop 1 WR pressure)

Temperature arms Train B, but pressure operates Train A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Train B LTOP Inputs

A

For PCV-456:
→Tcold 413B (Loop 1)
→Tcold 423B (Loop 2)
→T-hot 433A (Loop 3)
→T-hot 443A (Loop 4)
→PT-403 (Loop 4 WR pressure)

Temperature arms Train A, but pressure operates Train B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

LTOP is required when any CL temperature is…
(TS 3.4.12)

A

≤ 320°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When LTOP is required by TS 3.4.12, the following is also required to ensure no heat transients beyond LTOP capability occur:

A
  1. render all SIPs and one charging pump incapable of injection
  2. close and deactivate SI accumulator discharge valves
  3. preclude the start of RCPs if secondary water temperature is > 50°F above primary
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Per TS 3.4.12, LTOP applies Mode 4, 5, and 6 (when RV head on), but does not apply when all RCS CL temperatures > 320°F and all of the following are met:

A
  1. at least 1 RCP operating
  2. PZR level ≤ 92%
  3. Plant heatup rate is limited to 60°F per hour

Note: LTOP will still arm ≤350°F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When is LCO 3.0.4.b not applicable regarding LTOP?

A

When entering MODE 4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Which PORV opens faster on NOP/NOT overpressure? Which PORV opens faster on LTOP actuation?

A

Overpressure: PCV-455A, due to the PI Controller
LTOP: They open simultaneously

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What are the LTOP PORV setpoints for different temperatures?

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly