***FFP LWPD's Flashcards

(14 cards)

0
Q

What is the “Primary Consideration” in PDs constructed with LW materials?

A

Collapse, is ALWAYS the Primary Consideration in buildings constructed with LW material.
Ch.6 1.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

T/F

The “Primary Emphasis” is an Exterior Attack unless the fire is minor or confined to a small area.

A

TRUE

Ch. 6 4.1.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

T/F

In any building construction the critical area subject to failure as a result of fire is the point of connection.

A

TRUE

1.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Traditional PDs built of ordinary construction can collapse within___minutes when there is no ceiling to provide protection therefore exposing structural components. 1.6

A
20 Minutes  (1 Hour if protected)
1.6
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

In PDs with LW Materials, when fire extends from the building contents to its structural components, collapse can occur within how many minutes?

A

Within 5-10 minutes.

PD Ch6 1.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is of “Paramount Importance at a LWPD Fire?

A

Positioning the 1st hose line for early extinguishment or control of a contents fire that has not extended to the structural components.
1.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

T/F

Collapse in LW structures can occur suddenly and with little or no warning signs.

A

TRUE

1.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

LW construction often provides for the creation of large rooms. Areas unsupported by columns with spans > than___’ are generally an indication that LW construction is present.

A

> than 25 feet

1.8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What type of LW construction would a contractor use to span spaces over 60 feet?

A

Laminated wood I-Beams

3.3.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

T/F Unless the fire is minor, or confined to a small area, the PRIMARY EMPHASIS for a fire in a LW building UNDER CONSTRUCTION is that of an exterior attack.

A

TRUE Exterior streams should be positioned and operated from safe area outside the collapse zone 4.1.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is an indication that there is a fire in a trussloft?

A

The presence of smoke pushing at the floor line on the outside of a building. 4.1.12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

T/F When the above mentioned is evident at a PD fire, it is an indication that the probability of collapse is significantly increased.

A

TRUE Statement

4.1.12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Nozzle FFs should use the___method due to the potential of fire and heat weakening the floor system and causing a collapse.

A

…“Leg Forward” method…

4.2.6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

T/F

Under NO circumstances shall the roof be cut in any peaked or flat roof building of LW construction.

A

TRUE Statement

4.3.8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly