TB SCBA Scott 4.5 Positive Pressure SCBA Flashcards
(42 cards)
Hydrostatic testing is doneevery___years.
5 years. If the test date shows greater than 5 years, the cylinder must be removed from service, bled down, tagged and returned to MSU. It will be marked w a #. 102= tested in january of 2002. needs a retest in 2007. 3.2.4
The service life of an air cylinder is___years.
15 years. If a manufacture date is greater than 15 years, the cylinder must be removed from service, bled down, tagged, and returned to MSU.
3.2.3
SOC carried 10 minute escape bottles. How often do they need to be retested?
Every 3 years
3.2.4
All 4.5 cylinders are tested to___PSI.
4500 PSI
3.2.6
Vibralert and HUD actuate when approximately__% of full cylinder pressure remains in the cylinder and valve assembly.
25%
3.2.8
T/F
It is the individuals responsibility to know their working and exit time of the SCBA.
TRUE
3.2.8
Inspect all spare cylinders___ on ___ for full pressure.
Weekly on Monday. Stored cylinders found below full shall be tagged and returned to the MSU for further inspection. 3.2.12
Can SCBA cylinders with a blue top and / or a polymer protective sleeve be used for FF purposes?
NO These are training cylinders.
3.2.15
When replacing the nylon “O” Ring what tools are needed?
1/8” Allen wrench & a 7/16” open end wrench.
3.4.2
T/F
The UAC is for Emergency Use Only.
TRUE
3.5.1
The UAC MUST have it’s protective dust cover in place. If a SCBA is found without a UAC dust cover what shall be done?
SCBA placed OOS w RT2 and sent to MSU.
3.5.2
The PRA normally drops the high pressure air to __PSI before entering the regulators LP hose.
100 PSI
3.6.1
The regulator then controls the pressure within the face piece to»>
…to slightly above atmospheric pressure.
3.6.1
A malfunction of the PRA’s primary system will automatically direct breathing air into a secondary system. When this occurs the operating pressure will only be reduced to___PSI.
150PSI and cause the vibralert alarm to activate.
3.6.2
Failure of both primary and secondary systems in the open position will activate a relief valve in the PRA, which will rapidly discharge all pressure in excess of___PSI
185 PSI into the atmosphere.
3.6.3
When this occurs the cylinder valve should be___.
Partially closed.
3.6.3
If the manual shut off switch is not pressed, a 45 minute bottle of air can be depleted in__Minutes
approximately 4 minutes.
3.8.2.A
The spray bar has___small holes.
9
3.8.8
The HUD consists of___rectangle lights to represent the cylinder pressure at_,__,___&___.
Four lights Full 3/4,s full 1/2 1/4
3.8.9
A fifth round red light indicates____.
Low Battery
3.8.9
When cylinder is turned on, the HUD will initialize and illuminate all___ light for ___seconds.
5 light for 20 seconds.
3.8.9A
T/F
Operations of all five lights must be verified every time SCBA use has begun and with every regular operation inspection.
TRUE
3.8.9A
FULL Cylinder-indicated by…
…the 2 green lights glowing near the center off the display.
3.8.9B
Three quarters cylinder- indicated by…
…a single Green light glowing.
3.8.9B