Tower Ladders Flashcards

(48 cards)

0
Q

The basket while touching a point___feet horizontally from the center of the turn table can reach a basket floor elevation of ____ feet.

A

32’ horizontally

basket floor elevation of 65 feet.

3.2.2
FFP Ladder OPS:TLs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

A properly positioned TL provides wall coverage from grade level or below, up to a maximum floor level of___’ , at the maximum ___ degree angle.

A

Floor elevation of 70’

at the maximum 75 degree angle.

FFP Ladder Ops:TL’s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

TL Scrub area covers the front of the building ___ feet high and ___ feet wide, and will cover a ___ foot frontage on the lower ___ floors of a building.

A
60 feet high
50 feet wide
100 foot frontage
lower 3 floors
3.2.3
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

TL has a scrub area of approximately ____ square feet when the center of the turntable is ___feet from the building wall and cab is ___ degree angle away from the building line.

A

7750’

32’ from building

15 degree angle

3.2.4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The basket can reach ___ feet below grade.

A

10 below grade.

3.2.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Apparatus may be placed on the sidewalk either fully or partially to reach upper levels or to gain better vantage points. What must be done prior to doing this?

A

Verify the condition under the sidewalk and make certain that the stabilizers are on a firm foundation.

3.2.6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When the center line of turntable is___ feet from a building, there will be sufficient room for basket to be dropped below the horizontal with the boom perpendicular to the side of the apparatus.

A

25 feet from a building.

3.2.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Ideal horizontal distance from objectives is___ feet. At___feet from the center line of turntable to building, allowance is made for sidewalks, outriggers, and parked vehicles.

A

32 Feet

32 Feet

3.2.8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

While 75 feet is the nominal height, the actual working height (the bottom of the basket at its highest elevation), is little more than___feet when the boom is at the maximum angle of___dgrees.

A

little more than 70 feet

maximum angle of 75 degrees.

3.2.9

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Positioning apparatus ____ to the direction of the slope so that the operations will be in the “_____” direction’

A

Parallel to the direction…

“Up Hill” direction

3.4.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

If possible, apparatus should be facing____, e.g., if facing___, turntable____ the objective. If facing____, turntable____ objective.

A

should be facing “DOWN-HILL”

if facing DOWN-HILL turntable PAST the objective.

If facing uphill turntable before objective.

3.4.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Sudden___and____ should be avoided under___operatiing conditions.

A

STARTS and STOPS

under ALL operating conditions
3.4.4 note

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Grades up to ___ % slope may be treated as level ground.

A

Grades up to 4%

3.4.5 Note

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The MAXIMUM “slope” for TL operation has been set at___% grade by the manufacturer for a safe performance of apparatus.

A

15% grade…

3.4.6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

A difference of slightly over ___ feet from front to rear of apparatus approximately___% slope.

A

5 1/2 feet

15% slope’

3.4.6 note 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

On taking up, boom shall be raised to a ___degree angle, drains of waterway and the gated inlets opened to drain system of water.

A

raised to a 60 degree angle.

3..5.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What size of portable ladder is used when placed in the basket of a TL?

A

20 foot Portable Ladder (preferably a combination ladder) A 25’& 35’ can be used with great difficulty.
3 FFS maximum in bucket.
with 15’ of 1/2” rope fitted with a hose strap hook at one end.
This rope passes thru the 6th rung’
3.6.4A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

When used for ventilation purposes what MUST be placed in the bucket?

A
  1. Axe
  2. Halligan
  3. Power Saw
  4. 6’ hook
  5. LSR
  6. 1.2
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Personal Harness & LSR shall be used to limit travel of operator to a radius of no more than___feet from the basket.

A

No more than 10 feet from basket.

4.1.4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

This is done how?

A

LSR with a bowline 15 foot loop and personal harness tied to a substantial part of basket.
4.1.4

20
Q

T/F

saw is started in basket and then held outside the basket. It shall be kept outside basket until shut off.

A

TRUE

4.3.1 B.

21
Q

Initially the basket is elevated to a point where the ___ railing of bucket is level with the window ledge, or level with the top railing of the fire escape.

A

MIDDLE RAILING

5.1.2

22
Q

To facilitate removal of incapacitated or obese victims, position the___basket rail level with the window sill or top rail of fire escape.

A

position the TOP rail

5.1.2 B

23
Q

To expedite placing basket at window, place apparatus ____ to the objective so that the_____is in line with the window or target.

A

parallel to the objective

basket is in line

5.1.4

24
When using the TL basket for removal using the stokes stretcher. What are the 3 positions a stokes can be placed for removal? l
1. Upright 2. Diagonal 3. Lashed to the top railings' 5.2.1
25
What is the easier and safer placement of the stokes?
The DIAGONAL position | 5.2.1.Note
26
Who can order the use of TL streams?
Only the Officer in command of operations 6.1.1
27
What type of stream is preferred to protect people on the fire escape from fire?
A fog stream is preferred used at an acute angle to building.. Fog reduces injury to persons as opposed to solid stream. Fog reduces structural and water damage as opposed to solid stream. 6.1 example
28
When fire building is heavily involved on several floors, heavy stream delivery should generally start at the ____ level and work____. effecting a quick knockdown on the way__ to the __ floor and___.
Start at the LOWEST LEVEL work UPWARD UP to the TOP Floor andCOCKLOFT 6.2.2
29
The nozzle should be placed____and___in the window.
CLOSE TO AND LOW IN THE WINDOW | 6.2.3.
30
Where stability of the building is in doubt, the basket shall be placed___
...The basket should be placed at least the same distance horizontally from the building as it will be vertically below the top of the wall. 6.2.3 F
31
The stream shaper with a minimum tip size of____" Nozzle attached shall be normally carried on the Stang Nozzle to be used when a straight stream is ordered.
Minimum tip size is 1 1/2" nozzle 6.2.7
32
When a FOG Stream is ordered, the ___&____ shall be removed and the fog nozzle placed directly on the ___.
Stream shaper and TIPS are removed. directly on the looped barrel. 6.2.7
33
When not in use can the stang nozzle be secured to the railing of the basket?
It is NOT Recommended since vibration can weaken the railing. 6.2.8
34
Is it good practice to direct a stream from above roof area into openings to attack a cockloft fire?
NO It is generally counter productive. 6. 3.2 D 6. 3.3
35
Is it permissible to shut down water t the TL Siamese?
NO water should be shut down at the SUPPLY PUMPER. 6.5.1
36
What is the BEST source of water supply for a TL?
The Satellite Water Unit is the best Source (if available) | 6.6.1A
37
Supply water to base of TL at ___psi to ___psi.
200-250 PSI | 6.6.1 B
38
Relief Valve of TL should be set at___psi.
250 PSI. 6.6.1 C
39
How many sources of water are needed at the base of a TL?
Generally only ONE source. | 6..6.1.D
40
Generally nozzle pressures should not exceed___PSI with a relief valve setting of ___PSI.
Nozzle pressure 100PSI relief valve setting of 250 PSI 6.6.2C
41
Upon shutting down TL Stream, it shall be the duty of___ to survey each floor in regard to run-off, water laden stock, structural damage resulting from fire and/or operation of heavy caliber stream etc
Its the duty of the TL OFFICER | 6.7.1
42
Under most conditions what member of the TL shall maintain communications with the Satellite Water Unit?
The Pedestal Man 6.7.4
43
WHo shall monitor incoming pressures when a TL is being supplied?
Members of TL not engaged in operation of basket. 6.7.4
44
When members are working from the basket where should it be positioned?
The TOP Basket railing should be positioned slightly below work area. 7.1.2
45
A TL Basket has a capacity of ____lbs.
1000 lbs. This is a conflict confined space says TL = 800lbs
46
What is the preferred order of removal of people from a fire building?
``` 1 Interior Stairs 2 Horizontal Exits 3 Fire Escape 4 Ladders 5 LSR ``` L2 6.7
47
The basket of the TL can be positioned ___or___ above the street level and the TL Stream can be directed into the store.
a foot or two above the street. | FFP Taxpayer Fires 8.1.20