*TB 8- Electrical Hazards Flashcards Preview

Soriano-Tech > *TB 8- Electrical Hazards > Flashcards

Flashcards in *TB 8- Electrical Hazards Deck (63):
0

Terminology: Current flow or electron flow is known as?

AMPS

1

Terminology: The push or pressure behind current flow through a circuit is know as?

Volts

2

Terminology: _______ determines how much current will flow through a component.

Ohms

3

Amps x volts = ?

Watts (power)

4

High voltage is ranges from _____ to _____. Also referred to as "primaries"

600 to 59,999v

5

Low voltage is usually below _____ volts also referred to as "secondaries"

600v

6

Extremely high voltage is considered in excess of ______ volts

60,000v

7

All voltages above ________ volts are referred to as transmission voltages.

69,000v

8

Sub-transmission lines are considered to have __________ volts

34,500v

9

At a distribution station, electricity is received at ______ volts and stepped down to _____ volts

1. 34,500v

2. 4,800v

10

Lines that carry 4,800 volts and run from the distribution stations to the neighborhood it feeds are known as what "type" of power lines?

primary lines or "primaries"

11

A receiving station takes high voltage from transmission lines and steps the voltage down to what?

34,500 volts

12

A ___________ is designed to reduce the voltage in the system to a voltage usable by the consumer.

Transformer

13

Pole-mounted transformers are installed on 4,800v circuits and step the voltage down to _____ volts

120/240 volts

14

Underground electrical lines can be found in conduits or ducts and are identified by warning signs labeled ______

UG (underground)

15

Electrical distribution lines placed directly in the ground are designated as _________

DB (direct buried)

16

High voltage capacitors are dangerous because?

1. They can hold a charge for weeks even if power was shutdown to the circuit

2. Contain dangerous chemicals

17

________ are appliances which will prevent the flow of electricity and provides support to the conductor.

Insulators

18

Insulators are mostly made of _____ or _____

Glass or porcelain

19

The service connection that uses three conductors twisted around each other is know as a _______

Triplex

20

The 3 most effective methods of identifying high voltage on a pole are?

1. High voltage sign on cross arms

2. Size and shape of insulators (large = high volts)

3. Distance between conductors (wires)

21

What are the four main types of electrical injuries?

1. Electrocution
2. Electrical shock
3. Burns
4. Falls

22

Firefighters responding to emergencies involving electrical equipment must wear what kind of PPE's?

Full turnouts with hood and firefighting gloves

23

There are two main methods for de-energizing a building are?

1. Throw the main switch or breaker switched at electrical panel

2. Cut wires with LAFD equipment

24

Besides wearing full firefighting turnouts while shutting down power at the electrical panel, what else SHALL be worn?

Eye protection, consider scba face piece

25

Is the LAFD able to cut high voltage wires in the case of an emergency?

No, contact MFC to have DWP respond

26

Aerial ladders must be kept at least _____ feet away from all power lines and devices.

10ft

27

The aerial ladder shall not work in violation of the 10-foot rule from electrical wires unless?

Participating in a rescue attempt

28

During a rescue attempt with the aerial ladder, can any member remain at the pedestal to operate the ladder?

No, it SHALL be the apparatus operator

29

Even if a wire is not electrical, should it be considered charged?

Yes, additional wires may have fallen and charged them

30

Even overhead communication cable normally found on the lowest level of a power pole can be energized with up to _____ volts.

50v

31

If an apparatus becomes energized, what must be announced so other members on scene are aware of the danger?

Emergency traffic

32

If an apparatus becomes energized with a downed high voltage wire, can LAFD members raise or move the wire to de-energize the apparatus?

No, call for LADWP

33

Keep ground ladders at least ____ feet from wires

10ft

34

For a downed overhead wire, have responding personnel maintain at least ___ span(s) from the affected wire or pole

One

35

"One span" is considered the distance between how many poles?

2 poles

36

For optimum safety, the distance between how many undamaged poles will provide the best margin of safety?

2 undamaged poles

37

What should be the LAFD actions when water from a sheared hydrant is contacting overhead electrical wires?

Call and wait for DWP, unless a life hazard exists

38

What should be the firefighting actions for an overhead or pad mounted transformer fire?

Secure scene and protect exposures

Extinguish once DWP has de-energized

39

Streetlights can be fed from conductors carrying ____ to ____ volts or more.

120-6150v

40

Are street lights considered low or high voltage?

High voltage

41

What should be the firefighting actions for a street light fire?

Secure scene and protect exposures

Extinguish once de-energized by DWP

42

What should be the firefighting actions for a distribution/substation fire?

Secure scene and protect exposures

Extinguish once de-energized by LADWP

43

What are the LAFD actions in case of rescue in a distribution station?

Have victim remain stationary until LADWP gives clearance for rescue

44

What is the "rule" developed for using hose streams around high voltage?

What does it stand for?

30/33/100 rule

30 degree fog pattern
33 feet away from energized source
100psi minimum to nozzle

45

Where possible, extinguish small electrical fires with what two types of extinguishers?

Dry chemical or carbon dioxide extinguishers

46

The method to assure that fire personnel do not enter Life Hazard Zones includes the use of a minimum of ______ horizontal strands of barrier tape that state “Do Not Enter” or “Do Not Cross”.

3

47

If the driver of a vehicle in contact with downed wires is able to drive the vehicle, it should be driven clear of the wires by at least ____ feet.

35ft

48

Instructing victims to exit a charged vehicle should only be done when?

A life threatening emergency exists

49

The main fire hazard within electrical vaults lies in the _______ used in the transformers, which has a flash point below _____F.

1. Cooling oil

2. 300

50

How much do manhole covers weigh?

300 lbs

51

How high can a manhole cover be blown into the air and at what distance can it end up?

1. 75 ft

2. 125 ft

52

___ of an amp of electricity going through the body for just 2 seconds is enough to cause death

1/10th

53

When cutting wires at the drip loop with LAFD equipment, cut which wire (conductor) first?

Closest

54

Per T.B. 49:

All Water and Power capacitors, transforms, regulators, and resistors are labeled with a ___ inch x ___ inch yellow and black sign indicating that the equipment contains PCB's

2" by 2"

55

Voltages on transmission lines range from ___ kv to over ___kv.

Most of the transmission lines coming into Los Angeles are ____kv

60kv to 1000kv

230kv

56

Pad mounted transformers are connected to ___kv circuits and are located in parking lots of small and medium size businesses or in the front yard of some residences.

48

57

Underground distribution lines can be found in what three configurations?

-underground
-subsurface
-direct buried.

58

At 600 volts, the current through the body may be as great as ___ amps

4

59

Voltage _______ is a decreasing current created when a energized wire is in contact with the earth.

Gradient

60

What are the three significant methods that can result in electrocution at an emergency involving electrical equipment?

1. Voltage gradient
2. Touch potential
3. Step potential

61

What are the two methods used when instructing a patient to exit an electrically charged vehicle where a life treating emergency exists?

(Firefighters must not approach or grab victim)

Jump from the vehicle and:

1. Keeping feet together and taking small hops away
2. Shuffling feet together

62

A transformer vault has a _____ shaped manhole cover

Square