Flashcards in EVOLUTIONS 9 - SUPPLY A LINE FROM STANDPIPE Deck (9)
Loading flashcards...
0
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
What lengths does the nozzle connect during standpipe operations?
Nozzle connects hose butts between lead length and 2nd length
1
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
What lengths does the back-up man connect during standpipe operations?
Back up man connects hose butts between 2nd and 3rd lengths
2
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
What lengths does the control man connect during standpipe operations?
Control man connects inline pressure gauge and hose line to the standpipe outlet.
3
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
If the doorman is present what are his duties?
- Connects hose butts between 3rd and 4th lengths (if needed).
- Assists Control firefighter in hooking up to standpipe.
- Assists Nozzle and Backup firefighters.
4
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
All hoselines stretched from standpipe shall be _______ hose with controlling nozzle and _____ Main Stream Tip. All handlines should be stretched from ______________.
All hoselines stretched from standpipe shall be 2½" hose with controlling nozzle and 1⅛" Main Stream Tip. All handlines should be stretched from the floor below.
5
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
Variations from stretching initial hoselines from standpipe outlets on a floor below the fire due to building configurations shall be approved by _________________ and placed in the __________ program.
Variations from stretching initial hoselines from standpipe outlets on a floor below the fire due to building configurations shall be approved by DIVISION COMMANDER and placed in the CIDS program.
6
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
TRUE/FALSE
Controlling nozzle must always be carried attached to the folded lead length.
TRUE
7
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
The color markings for the standpipe system are as follows:
STANDPIPE -
AUTOMATIC SPRINKLER -
NON-AUTOMATIC SPRINKLER -
COMBINATION STANDPIPE/SPRINKLER -
STANDPIPE - RED
AUTOMATIC SPRINKLER - GREEN
NON-AUTOMATIC SPRINKLER - ALUMINUM
COMBINATION STANDPIPE/SPRINKLER - YELLOW
8