TOOLS 28 - LOBSTER TOOL Flashcards Preview

Undeleted > TOOLS 28 - LOBSTER TOOL > Flashcards

Flashcards in TOOLS 28 - LOBSTER TOOL Deck (13):
0

LOBSTER TOOL

DESCRIPTION

What units carry the lobster tool or cordless rebar cutter?

Ladders

Squads

Rescues

1

LOBSTER TOOL

DESCRIPTION

It can also be used to cut wrought iron fences up to _______ in diameter. It is not to be used to cut __________ or ________.

5/8"
CASE HARDENED STEEL RODS OR LOCKS.

It can also be used to cut wrought iron fences up to 5/8" in diameter. It is not to be used to cut case hardened steel rods or locks.

2

LOBSTER TOOL

EMERGENCY MANUAL RELEASE

How do you operate the emergency manual release?


After releasing the trigger switch, slightly loosen the release valve button.

The hydraulic oil will be discharged and the movable blade will return to its starting position.

Tighten the release valve to prepare the tool for the next operation.

3

LOBSTER TOOL

SAFETY

TRUE/FALSE

Do not operate this tool in a explosive atmosphere.

TRUE

DO NOT operate this tool in an explosive atmosphere, e.g. flammable liquids, gases or dusts. This tool creates sparks, which may ignite the dust or fumes.

4

LOBSTER TOOL

TECHNICAL DATA

What is the voltage that lobster tool works on?

12 volts

5

LOBSTER TOOL

TECHNICAL DATA

How much time does the quick charge require?

20 minutes

6

LOBSTER TOOL

TECHNICAL DATA

Below 32 degrees F, this tool _________ work well.

Below 32 degrees F, this tool WILL NOT work well.

- warm up prior to use by storing in heated area or using the trigger lock to run the tool for 5 mins without any load.

7

LOBSTER TOOL

TECHNICAL DATA

The tool is equipped with a swivel head that has a _________ degree turning angle to make it more convenient for the operator.

180 DEGREE

The tool is equipped with a swivel head that has a 180-degree turning angle to make it more convenient for the operator.

8

LOBSTER TOOL

TECHNICAL DATA

When the battery is low, what will happen?

- The battery capacity indicator is composed of five pilot lamps.

- When the battery is low, the pilot lamp display will flash to alert the operator that the remaining battery capacity is less than 20 percent.

9

LOBSTER TOOL

TECHNICAL DATA

A fully charged battery will last for aprx. _______ cuts.

40

A fully charged battery will last for aprx. 40 cuts.

10

LOBSTER TOOL

TECHNICAL DATA

Hydraulic oil should be changed every _______ months. Units shall do this on ___________ of each year.

6 MONTHS

JANUARY 1st and JULY 1st.

**tool room supplies hydraulic oil for lobster tool**

11

LOBSTER TOOL

TECHNICAL DATA

When are the batteries check on the lobster tool?

At the start of each tour.

12

LOBSTER TOOL

TECHNICAL DATA

In the event the lobster tool becomes inoperable, the company should contact ____________.

In the event the tool becomes inoperable, the company officer shall contact Technical Services. Technical Services maintains loaner tools that will be deliver to the company when picking up the out of service tool.