A LIST OF ALL CFR CERTIFIED MEMBERS, ALONG WITH THEIR CERTIFICATION EXPIRATION DATE AND THE RE-CERTIFICATION CLASS DATES WHEN SCHEDULED SHALL BE MAINTAINED WHERE?
OFFICE RECORD JOURNAL
more places than this
WHAT INCIDENTS ARE FIRE COMMUNICATIONS NOT ALLOWED TO DISPATCH A CFR UNIT TO?
INTOXICATIONS
WHAT UNITS CARRY DISPOSABLE BODY BAGS?
ALL EMS COMMAND AMBULANCES
CONDITIONS CARS
LSU AND MERV
DEPUTY CHIEFS
IN FLAT ROOFED BROWNSTONE BUILDINGS, WHAT IS THE SIZE OF THE COCKLOFT SPACE?
2 TO 3 FT IN HEIGHT
YOU ARE THE LT FOR THE NIGHT TOUR IN L136, RELOCATED TO CROWN HEIGHTS AND ARE CALLED FIRST DUE FOR A TOP FLOOR FIRE IN A BROWNSTONE BUILDING. UPON ARRIVAL THERE IS NO LIFE HAZARD SHOWING, WHERE SHOULD YOU INSTRUCT YOUR CHAUFFEUR TO POSITION THE AERIAL LADDER?
ROOF OF EXPOSURE
FOR A TOP FLOOR BROWNSTONE FIRE, WHAT IS THE FIRST DUE OVM (AERIAL LADDERS) TOOL ASSIGNMENT?
HALLIGAN
SAW
H.T.
FLASHLIGHT
FOR A TOP FLOOR FIRE IN A BROWNSTONE BUILDING, WHAT IS THE TOOL ASSIGNMENT OF THE 2ND ARRIVING AERIAL LADDERS ROOF MAN?
6FT HALLIGAN HOOK
SAW
H.T.
FLASHLIGHT
A TOWER LADDER ARRIVES FIRST DUE FOR A FIRE ON THE 3RD FLOOR OF A 4 STORY BROWNSTONE, THE BASKET HAS JUST DROPPED THE ROOF MAN OFF AT THE ROOF, UPON COMPLETION OF ROOF SIZE UP WHAT WOULD BE THE NEXT ACTION OF THE OVM INSIDE THE BASKET?
3RD FLOOR (FIRE FLOOR) VENTILATION
PUMP DISCHARGE PRESSURE WHEN SUPPLYING A SPRINKLER SYSTME SHOULD INITIALLY BE?
150 PSI
A LARGE CALIBER STREAM IS ANY FIRE STREAM WITH A FLOW OF HOW MANY GALLONS PER MINUTE OR MORE?
300 GPM
THE AKRON TOWER LADDER BASKET BASED MONITOR IS CAPABLE OF FLOWING HOW MANY GALLONS PER MINUTE?
1200 GPM
A COPY OF THE EMERGENCY ACTION PLAN MUST BE AVAILABLE FOR INSPECTION BY?
NYS PUBLIC EMPLOYEE HEALTH AND SAFETY (PESH)
WHAT IS THE SPECIFIC GRAVITY OF WATER?
1
NEWER TANKER TRUCKS HAVE ALUMINUM SHELLS WHICH REDUCE THE DANGER OF BLEVE DUE TO THE FACT THAT THE TANKS?
MELTING OF THE SHELL
WHERE IS THE BEST PLACE TO ESTABLISH A FOAM ASSEMBLY POINT FOR A FOAM CARRIER OR A FOAM TENDER?
AT AN INTERSECTION
HOW MANY TURNS DOES IT TAKE TO CLOSE A BUCKEYE PIPELINE VALVE?
42 FULL TURNS CLOCKWISE
WHAT ARE THE 3 FACTORS THAT WILL AFFECT THE IMPACT OF THE WIND WHEN DEALING WITH WIND DRIVEN FIRES IN HIGH RISE FIREPROOF BUILDINGS
- SIZE OF THE WINDOW OPENING
- FUEL LOAD INSIDE THE FIRE AREA
- STAGE OF FIRE WHEN THE WINDOW FAILS
WHEN IS THE LIST OF STORM OPERATIONS COORDINATORS UPDATE EACH YEAR? THIS IS IN RESPECT TO HURRICANES AND SEVERE STORMS.
MAY 1ST
ENGINE 8 IS ASSIGNED AS THE LOBBY CONTROL UNIT (E008L). WHAT LOCATIONS SHOULD THE LOBBY CONTROL UNIT LEADER VERIFY THE LOCATION OF?
FORWARD-FORWARD-SAFE FIRE
- FORWARD STAGING AREA
2 FORWARD TRIAGE AREA - FIRE FLOOR
- SEARCH AND EVACUATION POST (SAE)
THE MINIMUM REQUIREMENT FOR A VALID DNR AT A NURSING HOME IS?
PHYSICIAN’S SIGNATURE
WHAT IS THE PARAMOUNT CONCERN WHEN DECIDING IF THE 1ST HOSELINE SHOULD BE ADVANCED DOWN THE INTERIOR STAIRS AT A CELLAR FIREIN A PD?
SAFETY OF MEMBERS/RISK OF INJURIES TO MEMBERS
WHEN IS THE FAST PAK INSPECTED?
BEGINNING OF EACH TOUR
AFTER EACH USE
WHAT IS THE CORRECT TEN CODE FOR A SUBWAY TRAIN FIRE?
10-28 CODE 2
10-28 CODE 1 STRUCTURAL FIRE
(10-28 CODE 2 NON-STRUCTURAL FIRE)
(10-28 CODE 3 NON MEDICAL EMERGENCY)
WHAT IS THE PRIORITY ORDER OF VICTIMS DURING UNDER RIVER RAIL EMERGENCIES?
LOOK UP