1

All passive and active equipment shall support a forward bandwidth of

54 MHz to 1,002MHz (1 GHz)

2

All passive and active equipment shall support a return bandwidth of

5 MHz to 42 MHz

3

ANSI/SCTE code for ground blocks

129 2007

4

A F-port must have this at the base to accommodate weatherproofing devices.

a non-threaded area

5

The bonding wire attachment must accommodate this range of wire sizes

#6 AWG to #14 AWG solid copper

6

Cable specifications in all new installations

minimum Series 6 with a minimum foil-braid, tri-shield configuration that includes a bonded inner foil tape and outer foil bonded to the jacket and at least 77% braid coverage

7

ANSI/SCTE code for drop amplifiers

161 2009

8

ANSI/SCTE code for indoor f-81 splice connectors

02 2006

9

An F-81 indoor splice connector must have at least one end with what

threads all the way to the base of the port to accommodate panel nuts and mounting to wall plates

10

Plastic fasteners must be

UV and ozone stable

11

requirements for a clip gun

must use a half-round plastic insert to prevent crushing

12

ANSI/SCTE minimum mechanical and electrical specifications for all passive devices

153 2008

13

Cutting blades in all drop cable preparation tools shall be replaced

monthly

14

Why must drop cable preparation tools have a notch in the dielectric cutting blade

to prevent nicking or scoring of the center conductor

15

Locking terminators must have what inside

an internal 75-ohm resistor

16

When must a locking terminator be sealed

When a disconnected drop is parked on the locking terminator

17

Why must a thread protector have a uniform internal inside diameter through the full length of the thread proctector

It allows the thread protector to be installed from either direction and ensures secure compression of the sleeve over a variety of female F-port lengths

18

Why must wall plates have a 7/16-inch hex recess molded in the wall plate

to hold the F-81 and prevent it from turning

19

What are requirements for f-connectors

compression-type with 360-degree retention of the cable

20

How often should compression tools be inspected

monthly

21

What must be done to drop before changing its connector at the groundblock

Drop must be disconnected from live plant to minimize inadvertent injection of noise

22

All aerial drops must meet the requirements of what Article of the National Electrical Code at a minimum

Article 820

23

Cable used for aerial installations must have

messenger wire or integral self supporting strength member

24

Aerial drop cable must have what on the braid wires?

A non-flowing flooding compound

25

What is max allowable length of series 6 drop cable?

150 feet

26

Series-11 or QR-320 cable is permissible only for aerial drops when

it is greater than 150 feet in length AND where its use will improve RF forward signal levels to within acceptable ranges as defined in Section 9 of this standard, and will therefore eliminate the need for RF signal amplification in the home

27

What must be used to prevent the messenger wire from separating from the drop cable?

S cable clips

28

Aerial drops must not interfere with what at the pole?

climbing space

29

Aerial drop routing must follow what whenever possible?

power service drop

30

When an aerial drop crosses property lines outside of the municipal right-of-way, it is called

cable trespass