Pump 14 Flashcards

1
Q

The voice between relay pumping operations and water shuttle operations is typically base on ($$$$$$) and ($$$$$$) with which a jurisdiction and it mutual aid agencies have to work.

A

Training

Type of equipment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The three major components of a water shuttle operation;

A

The fill site
The shuttle route
The dumping site

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

One pumper positions at the water supply source and is used to fill empty water tenders. The pumper that is located here is generally referred to as the ($$$$$)

A

Fill site pumper

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The second pumper is located at or near the fire scene and is used to draft water from the portable water tank. This LOCATION is commonly referred to as the ($$$$$$). The pumper that is located here is typically called the ($$$$$)

A

Dump site

Dump site pumper

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Fill site pumpers should have a rated capacity of ($$$$$$)

A

1000 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Tenders that have water tanks with less than ($$$$$) and rapid unloading capabilities are the most efficient for used in water shuttle operations.

A

2500 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Because vacuum tenders are self filling from a static water source at a rate of ($$$$$$) with lift capacity of up to ($$$$), there is no need for a pumper or driver operator to be at the fill site. With discharge rates up to ($$$$$$) these units meet NFPA

A

2000 gpm
22 feet
1750 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Water tenders equipped with a fire pump must have a tank to pump line that is capable of supplying the pump with ($$$$$) until at least 80% of the water in the tank is emptied.

A

500 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Water tenders must be equipped with an external fill connection that is plumbed directly to the tank. This external fill connect toon should allow the tank to be filled at a minimum ($$$$$)

A

1000 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Water tenders should have at least on large tank discharge that is capable of emptying ($$$$)of the tank volume at 1000 gpm

A

90%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Because most water tender tanks are less than 6 feet tall, the back pressure created is less than ($$$)

A

3 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Gravity dumps usually employ ($$$$) or larger round or square piping with a valve that extends to the exterior of the apparatus.

A

8 inch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The success or failure of a water shuttle operation depends on these decisions

A

Location of the dump site
Location of the fill site.
Route of travel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When possible select a fill site that is capable of supplying at least ($$$$$)

A

1000 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly