What action is required if the CRD trip breaker is INOPERABLE?

A

Place in trip within 1 hour or 3.0.1 applies.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the restoration time for an INOPERABLE shunt trip?

A

Restore within 48 hours or trip the breaker.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the criteria for rod OPERABILITY?

A

Trip insertion time, misalignment <9” (<6.5%), rod can be exercised, and rod can be located with API/RPI.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the acceptable rod overlap range?

A

25% ± 5%.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the composition of control rods?

A

80% Ag, 15% In, 5% Cd.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the DSS actuation requirement?

A

Energize to actuate, RCS >2500# (2 of 2 logic).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What happens if the first rod reaches the out limit in API?

A

The rest of the group is allowed to withdraw for up to 12 seconds or until reaching out/in limit.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What does RPI do during rod misalignment correction?

A

Inhibits withdrawal of any rod >1% from the minimum RPI position in the group.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What triggers an Out Inhibit?

A

> 2 DPM SUR on Source Range, >3 DPM SUR on Intermediate Range, >60% power with 9” asymmetric and diamond in AUTO, or safety rods not out.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What causes a Sequence Inhibit?

A

3% deviation from overlap setpoint, shifting diamond to MANUAL and SEQUENCE OVERRIDE.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What causes an AUTO Inhibit?

A

Loss of ICS AUTO power, safety rods not at out limit, or neutron error > ±1%.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What does Source Interrupt protect against?

A

Stator damage (high temperature) and ratchet trip (low voltage).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What happens during Hi-Hi AC on 2 phases?

A

Shunt trips A/C (or B/D).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What happens during Lo-Lo AC on 2 phases on both trains?

A

Shunt trips all 4 AC breakers (Rx Trip).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What happens during Lo-Lo DC on 1 phase on both SRPS?

A

De-energizes both rods.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What triggers an Asymmetric Rod Fault alarm?

A

7” difference; 9” difference removes the rod from the average.

17
Q

What conditions trigger a runback due to asymmetric rod fault?

A

9” asymmetric and in-limit or 0%, or safety rod group off out-limit and 9” asymmetric.

18
Q

What does the Asymmetric Fault Bypass do?

A

Ignores all asymmetric faults, removes out inhibit if due to asymmetric fault, and stops dropped rod runback.

19
Q

What are the PIP power sources?

A

PIP Left → VBC, PIP Right → VBD, Green LED SBO Lights → VBB.

20
Q

What does “Rx Trip Confirmed” indicate?

A

It is sensed by 52 breaker contacts on CRD breakers OPEN or electronic trip from DSS, and it places the system in MANUAL and Sequence Override.

21
Q

What happens during a total loss of P1?

A

A reactor trip occurs.

22
Q

What is the consequence of losing the PG/M module?

A

It causes two control rods to drop.

23
Q

What are the RCS pressure/temp limits for CRD designed to ensure?

A

They ensure hydraulic buffer action during a reactor trip.

24
Q

What is the required action if regulating rods are in the RESTRICTED region?

A

Restore them within 24 hours.

25
What is the required action if regulating rods are in the UNACCEPTABLE region?
Initiate boration within 15 minutes and restore to the restricted region within 2 hours.
26
What does a blinking red light on a slice indicate?
It indicates a non-critical fault, but the slice is still functional.
27
Why do you open CRD-CB-1A before reclosing 1G-2A after maintenance?
To avoid large current swings.
28
Why is API used at 55% power?
It allows immediate verification that all control rods are fully inserted post-trip.
29
What happens when a sequence fault occurs?
The diamond transfers to MANUAL.
30
What does a solid red light on the PG/M module indicate?
On the second solid red light, the PG/M module goes to failed-safe and drops two rods.
31
What does a solid red light on SRPS indicate?
It indicates a fatal failure and that the system is no longer performing its function.
32
What is the operability status of a safety rod stuck at 97% but able to move between 94% and 97%?
The rod is considered operable since it is misaligned by less than 6.5%.
33
Why is Absolute Position Indication used at 55% power?
It allows immediate verification that all control rods are fully inserted following a trip.
34
What triggers AUTO inhibit?
A neutron error of ±1%.
35
What is the first indication of a rod stuck during insertion?
The PI panel fault indication for the affected rod will be illuminated yellow.
36
Is DCRDCS Zone 25% monitored or available on the PIP?
No, it is not monitored or available on the PIP.
37
Solid Red Light on SRPS
Indicates a fatal failure and the SRPS is no longer performing its function.
38
First indication of a rod stuck during insert
The PI panel fault indication for the affected rod will be illuminated YELLOW (API PIP screen does not detect it).