WASTE DISPOSAL - GASEOUS Flashcards

(18 cards)

1
Q

Gas release may be secured for how long if the tank is isolated with no inputs and SM permission?

A

Up to 12 hours without needing a new permit. Permit allows up to 48 hours before starting.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What action should be taken if tank pressure decreases during a release other than the tank being released?

A

Terminate the gas release.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What must be done when venting MU-T-1 via MU-V-13?

A

Manually start WDG-P-1A or B in HAND.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What happens if VBD is lost and RM-A-7 loses power?

A

Verify WDG-V-47 AUTO closes, place RM-A-7 in DEFEAT, and resume release if RM-A-8 is OPERABLE.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are indications of a lifting relief valve?

A

Unexpected loss of decay tank pressure and RM-A-8 counts/alarm.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What happens if WDG-P-1A/B is started manually and trips?

A

The standby compressor starts and will NOT unload, requiring manual securing.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

At what pressures do the header N2 supply valves operate?

A

0.7# N2 supply OPENS, 0.9# N2 supply CLOSES, 1.4# decreasing trips WDG-P-1A/B, 1.6# starts WDG-P-1A, 1.8# starts WDG-P-1B.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What must be OPEN to start the waste gas compressor?

A

NS-V-32 must be OPEN.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the function of the separator tank in the waste gas system?

A

Maintained at 50# for seal water circulation and cooling through the compressor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What happens in the decay tank sequencer when the inlet valve closes at 80#?

A

The next tank in the sequence (A-B-C-A) is selected if the new tank is <80# and both outlets are CLOSED. Reliefs open in 8 minutes.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What protection do loop seals provide?

A

Overpressure protection at 8.5# (RCBTs/MWST) and vacuum protection at 3.25 psia.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How often are grab samples required if Beckman monitors are OOS?

A

Every 24 hours if 1 Beckman is OOS, every 4 hours during degas if 2 Beckmans are OOS.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What conditions terminate a gas release?

A

WDG-V-47 CLOSES on RM-A-7 High, RM-A-8 High, FR-123 High Release Rate, or AH-E-14A/B/C/D NOT running.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What happens to WDG-V-3/4 during specific conditions?

A

CLOSE on 4# ES, RTI, or RM-G-20 High.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the decay tank curie limit to ensure offsite dose remains below 0.5 Rem total body?

A

≤8,800 Curies.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the oxygen limit in the decay tank if hydrogen is ≥4%?

A

O2 must be ≤2%, or suspend additions immediately.

17
Q

What are the release requirements for RM-A-7 and FT-123?

A

Both must be OPERABLE. If not, WDG-V-47 CLOSES (terminated), or RM-A-8 + FT-149 + FT-150 must be OPERABLE (release continues).

18
Q

What must be done if a waste gas compressor is started manually?

A

The compressor must be STOPPED manually. Suction valves are interlocked to auto-open.