INCORES Flashcards
SPND signals reliability
SPND signals are NOT reliable at temperatures >1000°F and should NOT be used at <15% power.
Waiting time for incore readings after power change
Must wait 5 minutes after a power change to use incore readings and 10 minutes for calibration (Rh decay).
T.S. 3.5-2 requirement for BIRO incore thermocouples
2 of 4 BIRO incore thermocouples per quadrant must be OPERABLE; restore in 7 days or be in HSD in 6 hours and CSD in 30 hours.
Incore thermocouples requirement during RCS drain-down
2 incore thermocouples must be OPERABLE and in the core when RCS is drained down to below the tops of hot leg nozzles.
T.S. 3.5.2.4 Quadrant Tilt action
Exceeding the tilt limit requires reducing reactor power by 2% for each 1% in excess of the tilt limit.
T.S. 3.5.2.7 Axial Imbalance action
If an acceptable axial power imbalance is NOT achieved in 24 hours, reduce reactor power to ≤40% FP within 2 hours.
T.S. 3.5.2.8 Power map requirement
Must perform a power map within limits of COLR every 31 days.
BIRO thermocouples operability requirement
With <2 BIRO thermocouples per quadrant OPERABLE, restore in 7 days or be in HSD in 6 hours and CSD in 30 hours.
Importance of tilt and imbalance drawings
Know the tilt and imbalance drawings in Tech Specs to differentiate between conditions.