NUCLEAR CHEMICAL ADDITION Flashcards

(15 cards)

1
Q

What is the maximum rate for adding boric acid to the mix tank?

A

Do not add boric acid to the mix tank at a rate of >1000lbs/hr.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Why should boric acid not be added to the mix tank at a rate exceeding 1000lbs/hr?

A

Adding boric acid at a rate >1000lbs/hr is endothermic and can cause boron to rock up.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the minimum borated water concentration required by COLR?

A

Alternate source of borated water >12,500ppm; 7% mix tank (CA-T-1) is credited.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What powers CA-P-1A/B pumps, and what is required for their operation?

A

Powered by 1A/B ES MCC; stroke counter on LWDS must be >0 to run pump, TRIP @ 0.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What bypasses LWDS and Chem Add panel for CA-P-1A/B pumps?

A

A key-operated switch at CA-P-1A/B breakers for RSD.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What happens to “A” BAMT heaters and BAMT Mixer during “A” ESAS load shed?

A

They are load shed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What powers the caustic pump (CA-P-4)?

A

Powered by 1C ESV.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the preferred source of reclaimed water, and why?

A

Ecolochem is preferred to limit dissolved O2.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How is the reclaimed water tank maintained to limit O2 intrusion?

A

Maintained at 1-2# N2 overpressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What does CA-V-133 do, and what happens when it opens?

A

CA-V-133 opens to maintain 4-6’ (55-75#) in CA-T-7 (reclaimed water pressure tank); CA-P-6 auto starts on valve opening.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What powers CA-V-189, and what are its failure modes?

A

Powered by 1M DC; closes on RTI and 4# ES, fails closed on loss of air/power.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the power source for CA-V-189?

A

1M DC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What happens to CA-V-189 on RTI or 4# ES?

A

It CLOSES.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the fail-safe position of CA-V-189 on loss of air or power?

A

It fails CLOSED.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What does CA-V-189 provide water to?

A

The Reactor Coolant Drain Tank (RCDT).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly