REACTOR COOLANT PUMPS Flashcards

(11 cards)

1
Q

What is the purpose of the RCP flywheel?

A

The flywheel adds mass to the RCP motor to increase coastdown time, ensuring adequate flow following loss of all 4 RCPs for protection from DNB.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What does the high-pressure lift oil system do for RCPs?

A

It reduces breakaway torque of pumps, is started before starting the RCP, and stopped after the RCP is running. AC lift oil pumps get 27/86 lockout.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the starting interlocks for RCPs (SCORE)?

A

-RSC: >407°F for 4th pump
-Seals: >22 gpm AND ICCW >550 gpm
-Cooling: NS pump 52 breaker contacts close
-Oil: Oil levels adequate
-Rx: <30% power cold water/react accident
-Electrical: Motor starting UV <6.62 kV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the automatic trip conditions for RCPs (SOUPS)?

A
  • Short Circuit
  • Overcurrent
  • Undervoltage
  • Phase Differential
  • Seal Injection (<22 gpm SI and ICCW <550 gpm for 10 sec)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When should an RCP be manually tripped?

A
  • Radial bearing temp >225°F
  • CBO >260°F
  • > 1700 psid on single seal
  • > 20 mils pump or >4 mils motor vibration
  • Loss of 25°F SCM within 1 minute
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the critical seal differential pressure (DP) for RCPs?

A

Hi-2 PPC alarm at 1700 psid requires pump shutdown. CBO >260°F requires the pump to be placed in standby.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the cooling requirements for RCPs from Nuke Services?

A
  • 80 gpm to motor air cooler
  • 60 gpm to #1 upper oil cooler
  • 60 gpm to #2 upper oil cooler
  • 8 gpm to lower oil cooler
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the power sources for RCP feeder and motor breakers?

A
  • 6.9 kV Feeder Breakers = E DC
  • RCP Motor Breakers = F (B) DC
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What happens to RCPs on loss of ICS AUTO power?

A

SI/ICCW trip and starting interlock for RCPs become inoperable.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the seal CBO flow rate for RCPs during normal operation and SBO?

A

2.5 gpm per pump during normal operation and 1 gpm per RCP during SBO when abeyance seal actuates.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What happens to the AC oil lift pump on an RCP trip?

A

The AC oil lift pump will start, and the loop with the 2 pumps still running will increase slightly.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly