WASTE DISPOSAL - LIQUID Flashcards

(16 cards)

1
Q

What happens if the Rad Monitor interlock is in DEFEAT and the rad monitor is de-energized?

A

The interlock will NOT actuate.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What action is required if RM-L-6 fails HIGH and WDL-V-257 sticks OPEN?

A

Terminate the release IAW C-1-1.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the RBAT Emergency Boration flowpath?

A

Through WDL-V-61 and the Batch Controller vs. BAMT through MU-V-51.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What happens on a High Alarm for RM-L-6/7?

A

WDL-V-257 CLOSES, but the release pump keeps running.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the valve lineup for a Liquid Waste Release?

A

WDL-V-257 FULL OPEN, WDL-V-124/125 throttled for flow control, WDL-V-128 FULL OPEN.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What happens if WDL-V-124/125 pressure loaded fails to max pressure?

A

The release would terminate on high rate.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the ODCM limits for public exposure at the boundary?

A

1.5 mR/quarter total body and 5 mR/quarter organ dose.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the maximum flow rate for Waste Transfer Pumps (WDL-P-6A/B/C)?

A

Do NOT exceed 160 gpm to prevent damage.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What components are required for system OPERABILITY?

A

1 Evap, 1 Condensate Demin, 1 WECST, and 1 Evap Condensate Pump.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Why should RC Evap NOT be used for Miscellaneous wastes?

A

It is required as a second source of boric acid for emergency boration per the COLR.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What conditions terminate a liquid waste release?

A

Loss of air, High RM-L-6/7, exceeding FT-84 setpoint, or insufficient MDCT dilution flow (FT-146).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How long must WECST be on recirculation before sampling for release?

A

8 hours.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What must run for the entire liquid waste release?

A

WDL-P-14A/B.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Why is timely rad waste processing of CCB important?

A

To reduce personnel exposure in the OOB (ALARA).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Can WDL-FR-84 radwaste release flowrate to plant effluent be monitored from the control room?

A

No, it cannot be monitored from the control room.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Where is the Decant Slurry control panel located?

A

On the West Wall adjacent to the Decant Pump Room at 281’ AB. Indication is ONLY at the Rad Waste Panel.