Evolutions 9, 10, 22 Flashcards

0
Q

All hose lines stretched from standpipe shall be _____ hose and ______ main stream Tip?

A

2 1/2 hose with a 1 1/8 MST

Evolution 9 page 3 note A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

T or F: When setting up folded hose lengths by the standpipe. You would be correct in putting the the length with the nozzle most close to the standpipe in the direction of the stretch?

A

False.
You would be correct in putting the length with the nozzle most DISTANT from the standpipe facing the stretch?
Evolution 9 sec. 3.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Variations from stretching initial hose lines from standpipe outlets on a floor below the fire due to building configurations shall be approved by _______ _______ and placed in the CIDS program?

A. Battalion Chief
B. Division Commanders
C. Borough Commanders
D. Chief of Operations

A

B. Division Commander

Evolution 9 page 3 note A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

T or F: If a pressure reducing device PRD cannot be removed and there is no others outlet available with out a PRD, then it is permissible to use an outlet with a PRD?

A

TRUE.

Evolution 9 page 3 note B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
What are the colors for Siamese outlet Caps:
Standpipe is Red
Sprinkler is Green
Non-automatic is ?
Combination is ?
A
Standpipe is Red
Sprinkler is Green
Non-automatic is Aluminum
Combination is Yellow
Evolution 9 page 3 note E
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When supplying water to the standpipe system through hose outlet valve inside the building you will need which size adaptors to connect the 3-1/2” supply line to the outlet inside the building?
A. 3”x 2-1/2” reducer to hose line to double male to the outlet
B. 3”x 2-1/2” reducer to hose line to double female to the outlet
C. 3-1/2”x 3” reducer to hose line to double male to the outlet
D. 3-1/2” x 3” reducer to hose line to double female to the outlet

A

B. 3”x 2-1/2” reducer to 3-1/2” hose line to double female connection to the outlet
Evolution 10 sec 3.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When supplying water to the standpipe system through hose outlet valve inside the building. Instead of using a 3”x 2-1/2” reducer to the 3-1/2” hose line to a double female to the outlet. You can use a 2-1/2” x 3” increaser on the standpipe outlet with a double female? T or F

A

True

Evolutions 10 note C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

T or F: When stretching a line via an Aerial ladder the officer climbs the ladder and enters the window and surveys conditions. When he orders a line to be advanced up only the first two members need to wear life belts?

A

False.
The first 3 members must have life belts on to snap into aerial rungs.
Evolution 22 sec 3.4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

T or F: When an officer orders a line stretched up the aerial ladder the first member (usually Nozzle man (book says No. 1)) climbs to the turntable; the Nozzle is passed up to him. Nozzle FF (No 1), placing the hose under his left arm and nozzle over his right shoulder then climbs the ladder, No 2 and No 3 follow No 1 lightening up on the line. No 1 snaps into the top rung and passes nozzle and hose in over sill to the officer who holds the line.

A

True
Evolutions 22 Sec 3.4
This evolution is basically 1 page. I would recommend reading it a couple of times since they use No 1,2,3,4,5 instead of saying Nozzle, backup, control, etc. It’s written poorly, but is pretty easy.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
When stretching a line via the Aerial ladder the hose should be placed on the \_\_\_\_\_ side?
A. Right
B. Left
C. Middle
D. Position of comfort
A

B. Left

evolutions 22 page 2 note A